본문 바로가기

QUANTITATIVE ANALYSIS OF HELICAL FLOW WITH ACCURACY USING ULTRASOUND SPECKLE IMAGE VELOCIMETRY: &ITIN VITRO&IT AND &ITIN VIVO&IT FEASIBILITY STUDIES

Quantitative Analysis of Helical Flow with Accuracy Using Ultrasound Speckle Image Velocimetry: In Vitro and in Vivo Feasibility Studies

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ULTRASOUND IN MEDICINE AND BIOLOGY44(3) · pp.657 · 2018
피인용
Web of Science 8Scopus 9
FWCI (Scopus)
0.73
JCR IF
JCR 2017 2.645
ISSN
0301-5629

저자

  1. Lee, Sang Joon제1저자교신저자Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, South Korea
  2. Park, Jun HongDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, South Korea
  3. Kim, Jeong JuDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, South Korea
  4. 염은섭School of Mechanical Engineering, Pusan National University, Busan, South Korea

초록

Venous valve dysfunction and induced secondary abnormal flows are closely associated with venous diseases. Thus, detailed analysis of venous valvular flow is invaluable from biological and medical perspectives. However, most of the previous studies on venous perivalvular flows were based on qualitative analysis. On the contrary, quantitative analysis of perivalvular flows has not been fully understood. In this study, we used the ultrasound speckle image velocimetry (SIV) technique, which utilizes the speckle patterns of red blood cells (RBCs) created by ultrasound waves to measure 3-D valvular flows quantitatively. The flow structures obtained with the proposed SIV technique for an in vitro model were compared with those obtained by numerical simulation and the color Doppler method to validate the measurement accuracy of the ultrasound SIV technique. Blood flow in the human great saphenous vein was then measured at various distances from the valve with and without exercise. 3-D valvular flow was analyzed in accordance with the dimensionless index, helical intensity. The results obtained by the proposed method matched well with those obtained by numerical simulation and the color Doppler method. The hemodynamic characteristics of 3-D valvular helical flow which were analyzed experimentally using the SIV method would be used for quantitative diagnosis of venous valvular diseases. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

키워드

Ultrasound speckle image velocimetryHelical flowVenous valveHelical intensityBLOOD-FLOW3-DIMENSIONAL FLOWVEINSPATTERNSTRESSSYSTEMBYPASSVALVESPIV

식별자

Scopus EID
2-s2.0-85039058150
WoS UID
000425842800015