Effectiveness and Safety of Biolimus A9 (TM)-Eluting stEnt in Patients with AcUTe Coronary sYndrome; A Multicenter, Observational Study (BEAUTY Study)
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- YONSEI MEDICAL JOURNAL59(1) · pp.72 · 2018
- 피인용
- Web of Science 2Scopus 3KCI 0
- FWCI (Scopus)
- 0.12
- JCR IF
- JCR 2017 1.564
- ISSN
- 0513-5796
저자
- Park, Keun-Ho제1저자Division of Cardiology, Department of Internal Medicine, Chosun University Hospital, Gwangju, South Korea
- Jeong, Myung Ho교신저자Division of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, South Korea
- Hong, Young JoonDivision of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, South Korea
- Ahn, YoungkeunDivision of Cardiology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, South Korea
- Kim, Hyun KukDivision of Cardiology, Department of Internal Medicine, Chosun University Hospital, Gwangju, South Korea
- Koh, Young YubDivision of Cardiology, Department of Internal Medicine, Chosun University Hospital, Gwangju, South Korea
- Kim, Doo IlDivision of Cardiology, Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, South Korea
- Kim, Sang WookDivision of Cardiology, Department of Internal Medicine, Chung-Ang University Hospital, Seoul, South Korea
- Kim, WeonDivision of Cardiology, Department of Internal Medicine, Kyung Hee University Hospital, Seoul, South Korea
- Rha, Seung WoonDivision of Cardiology, Department of Internal Medicine, Korea University Guro Hospital, Seoul, South Korea
- Rhew, Jay YoungDivision of Cardiology, Department of Internal Medicine, Presbyterian Medical Center, Jeonju, South Korea
- Park, Jong SeonDivision of Cardiology, Department of Internal Medicine, Yeungnam University Hospital, Daegu, South Korea
- Park, Hun SikDivision of Cardiology, Department of Internal Medicine, Kyungpook National University Hospital, Daegu, South Korea
- Bae, Jang HoDivision of Cardiology, Department of Internal Medicine, Konyang University Hospital, Daejeon, South Korea
- Bae, Jang-WhanDivision of Cardiology, Department of Internal Medicine, College of Medicine, Chungbuk National University, Cheongju, South Korea
- Oh, Seok KyuDivision of Cardiology, Department of Internal Medicine, Wonkwang University Hospital, Iksan, South Korea
- Lee, Sung YunDivision of Cardiology, Department of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang, South Korea
- Lee, Seung WookDivision of Cardiology, Department of Internal Medicine, Gwangju Christian Hospital, Gwangju, South Korea
- Lee, Jae HwanDivision of Cardiology, Department of Internal Medicine, Chungnam National University Hospital, Daejeon, South Korea
- Lim, Sang YeobDivision of Cardiology, Department of Internal Medicine, Korea University Ansan Hospital, Ansan, South Korea
- Cho, Jang HyunDivision of Cardiology, Department of Internal Medicine, Saint Carollo Hospital, Suncheon, South Korea
- 차광수Division of Cardiology, Department of Internal Medicine, Pusan National University Hospital, Busan, South Korea
- Chae, Jai KeonDivision of Cardiology, Department of Internal Medicine, Chonbuk National University Hospital, Jeonju, South Korea
- Hur, Seung HoDivision of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, South Korea
- Hwang, Sun HoDivision of Cardiology, Department of Internal Medicine, Gwangju Veterans Hospital, Gwangju, South Korea
- Hwang, Jin YongDivision of Cardiology, Department of Internal Medicine, Gyeongsang National University Hospital, Jinju, South Korea
초록
Purpose: This study sought to determine the 1-year clinical effectiveness and safety of a biodegradable, polymer-containing Biolimus A9 (TM)-eluting stent (BES) in Korean patients with acute coronary syndrome (ACS). Materials and: A total of 1000 ACS patients with 1251 lesions who underwent implantation of BESs at 22 centers in Korea were enrolled between May 2011 and July 2013. We assessed major adverse cardiac events (MACE) defined as the composite of cardiac death, non-fatal myocardial infarction (MI), and clinical-driven target vessel revascularization at 12 months. Results: Patient mean age was 62.6 +/- 11.4 years. 72.8% of the patients were male, 28.5% had diabetes, 32.8% had multi-vessel disease (MVD), and 47.9% presented with acute MI (AMI). The mean global registry of acute coronary events risk score of all patients was 103.0 +/- 27.6. The number of stents per patient was 1.3 +/- 0.6. The incidences of MACE and definite stent thrombosis at 12 months were 3.9% and 0.2%, respectively. On multivariate Cox-regression analysis, age >= 65 years was identified as an independent predictors of 1-year MACE (hazard ratio=2.474; 95% confidence interval=1.202-5.091). Subgroup analyses revealed no significant differences in the incidence of MACE between patients with and without diabetes (4.3% vs. 3.7%, p=0.667), between those who presented with and without AMI (4.4% vs. 3.4%, p=0.403), and between those with and without MVD (4.6% vs. 3.5%, p=0.387). Conclusion: Our study demonstrated excellent 1-year clinical outcomes of BES implantation in patients at low-risk for ACS.
키워드
Biolimus-eluting stentbiodegradable polymeracute coronary syndromeDRUG-ELUTING STENTSACUTE MYOCARDIAL-INFARCTIONDUAL ANTIPLATELET THERAPYNON-INFERIORITY TRIALBARE-METAL STENTSBIODEGRADABLE POLYMERDURABLE POLYMERCLINICAL-OUTCOMESRANDOMIZED-TRIALSDIABETES-MELLITUS