Development of a Novel Detachable Magnetic Nerve Stimulator for Intraoperative Neuromonitoring
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- WORLD JOURNAL OF SURGERY42(1) · pp.137 · 2018
- 피인용
- Web of Science 15Scopus 17
- FWCI (Scopus)
- 1.36
- JCR IF
- JCR 2017 2.766
- ISSN
- 0364-2313
저자
- 성의숙제1저자Department of Otolaryngology - Head and Neck Surgery and Research Institute for Convergence of Biomedical Science and Technology, College of Medicine, Pusan National University, Yangsan, South Korea
- 이진춘Department of Otolaryngology - Head and Neck Surgery and Research Institute for Convergence of Biomedical Science and Technology, College of Medicine, Pusan National University, Yangsan, South Korea
- 신성찬Department of Otolaryngology - Head and Neck Surgery, College of Medicine and Medical Research Institute, Pusan National University, Busan, South Korea
- 최성원Department of Otolaryngology - Head and Neck Surgery, College of Medicine and Medical Research Institute, Pusan National University, Busan, South Korea
- 정다운Department of Otolaryngology - Head and Neck Surgery, College of Medicine and Medical Research Institute, Pusan National University, Busan, South Korea
- 이병주교신저자Department of Otolaryngology - Head and Neck Surgery, College of Medicine and Medical Research Institute, Pusan National University, Busan, South Korea
초록
Recurrent laryngeal nerve (RLN) palsy is a serious complication of thyroid surgery. During intraoperative neuromonitoring (IONM) of the RLN in thyroid surgery, repeated shifting between surgical instruments and the nerve stimulator is cumbersome and time-consuming. Therefore, we developed a simple detachable magnetic nerve stimulator that may be connected to all metallic surgical instruments. This study aimed to investigate the feasibility and efficacy of this detachable magnetic nerve stimulator for IONM in a porcine model and humans. Eight RLNs in four pigs and thirteen in nine patients that underwent thyroidectomy were examined. We developed a detachable nerve stimulator that combined surgical instruments with the nerve-stimulating probe. We evaluated the electromyography (EMG) amplitudes of the RLNs in pigs and patients using conventional nerve probes and surgical instruments with the novel detachable magnetic nerve stimulator attached. The EMG amplitudes of the eight RLNs in pigs and thirteen in patients were analyzed. The detachable magnetic nerve stimulator was feasible and safe. There was no significant difference in the EMG amplitude between instruments (P = 0.423 in animals, P = 0.446 in humans). The application of stimulating dissection using a detachable magnetic nerve stimulator during thyroidectomy with IONM is simple, convenient, and effective. It provides surgeons with real-time feedback of the EMG response during intermittent IONM. We propose that this novel device could be an essential guide for most surgeons, especially for less experienced head and neck surgeons.
키워드
RECURRENT LARYNGEAL NERVETHYROID-SURGERYPORCINE MODELINJURYIDENTIFICATIONRLN