Vertical Macular Asymmetry Measures Derived From SDOCT for Detection of Early Glaucoma
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE58(10) · pp.4310 · 2017
- 피인용
- Web of Science 15
- JCR IF
- JCR 2016 3.303
- ISSN
- 0146-0404
저자
- Sharifipour, Farideh제1저자Glaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
- Morales, EstebanGlaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
- 이지웅Glaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
- Giaconi, JoAnnGlaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
- Afifi, Abdelmonem A.Department of Biostatistics, Jonathan and Karin Fielding School of Public Health, University of California Los Angeles, Los Angeles, United States
- Yu, FeiGlaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
- Caprioli, JosephGlaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
- Nouri-Mahdavi, Kouros교신저자Glaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, United States
초록
PURPOSE. To test the hypothesis that vertical asymmetry in macular ganglion cell/inner plexiform layer (GCIPL) thickness can improve detection of early glaucoma. METHODS. Sixty-nine normal eyes and 101 glaucoma eyes had macular imaging with spectraldomain optical coherence tomography (OCT; 200 3 200 cube). The resulting GCIPL thickness matrix was grouped into a 20 3 20 superpixel array and superior superpixels were compared to their inferior counterparts. A global asymmetry index (AI) was defined as the grand mean of the asymmetry ratios. To measure local asymmetry, the corresponding thickness measurements of three rows above and below the horizontal raphe were compared individually and in combinations. Global and local AIs were compared to the best-performing GCIPL thickness parameters with area under the receiver operating curves (AUC) and sensitivity/specificities. RESULTS. Age or axial length did not influence AIs in normal subjects (P >= 0.08). Global and local AIs were significantly higher in the glaucoma group compared to normal eyes. Minimum (AUC = 0.962, 95% confidence interval [CI]: 0.936-0.989) and inferotemporal thickness (AUC = 0.944, 95% CI: 0.910-0.977; P = 0.122) performed best for detection of early glaucoma. The AUC for global AI was 0.851 (95% CI: 0.792-0.909) compared to 0.916 (95% CI: 0.874-0.958) for the best local AI. Combining minimum or inferotemporal GCIPL thickness and the best local AI led to higher partial AUCs (0.088 and 0.085, 90% specificity, P = 0.120 and 0.130, respectively) than GCIPL thickness measures. CONCLUSIONS. Macular vertical thickness asymmetry measures did not perform better than sectoral or minimum GCIPL thickness for detection of early glaucoma. Combining local asymmetry parameters with the best sectoral GCIPL thickness measures enhanced this task.
키워드
optical coherence tomographyearly glaucomavertical macular thickness asymmetryasymmetry indexganglion cell/inner plexiform layerOPTICAL COHERENCE TOMOGRAPHYNERVE-FIBER LAYERGANGLION-CELL COMPLEXOPEN-ANGLE GLAUCOMAPREPERIMETRIC GLAUCOMARETINAL-THICKNESSOCULAR HYPERTENSIONTENSION GLAUCOMADOMAIN OCTSD-OCT
식별자
- WoS UID
- 000410940400061



로그인
연구물 목록으로