Fitting miniscleral contact lenses in Korean patients with keratoconus
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q4Scopus Q2
- 저널
- CLINICAL AND EXPERIMENTAL OPTOMETRY100(4) · pp.375 · 2017
- 피인용
- Web of Science 13Scopus 18
- FWCI (Scopus)
- 1.18
- JCR IF
- JCR 2016 1.256
- ISSN
- 0816-4622
저자
- 김수진제1저자Department of Ophthalmology, Gyeongsang National University Changwon Hospital, School of Medicine, Gyeongsang National University, Changwon, South Korea
- 이종수Department of Ophthalmology, School of Medicine, Pusan National University, Busan, South Korea
- 박영기YK Eye Clinic, Seoul, South Korea
- Lee, Seung UkDepartment of Ophthalmology, School of Medicine, Kosin University, Busan, South Korea
- Park, Young MinDepartment of Ophthalmology, Gyeongsang National University Changwon Hospital, School of Medicine, Gyeongsang National University, Changwon, South Korea
- 이종헌Department of Ophthalmology, School of Medicine, Pusan National University, Busan, South Korea
- 이지은교신저자Department of Ophthalmology, School of Medicine, Pusan National University, Busan, South Korea
초록
Background: The aim was to evaluate the clinical results of fitting MSD miniscleral contact lenses (MSD; Happy Vision Corp, Anyang, Korea) in Korean patients with keratoconus. Methods: This report presents a retrospective case review of 38 keratoconic patients fitted with MSD lenses. Visual acuity, comfort, mean wear time, final lens parameters, relationships between sagittal depth and topographic indices, success rate with the first lens ordered and adverse events were documented. Results: The mean logMAR visual acuity was improved from 0.85 +/- 0.78 with glasses and 0.28 +/- 0.29 with corneal rigid gas-permeable lenses to 0.10 +/- 0.11 with miniscleral contact lenses. Ninety-seven per cent of patients found the miniscleral contact lenses to be comfortable and the mean daily wear time was 10.1 +/- 2.3 hours. The mean sagittal depth was 4.70 +/- 0.35mm and there was no correlation between sagittal depth and topographic indices. An average of 3.4 trial lenses was needed to decide the ordered lens and 1.3 ordered lenses to achieve the optimal fitting. One patient discontinued the wear of the lenses after three months due to discomfort. Conclusion: The use of MSD miniscleral contact lenses is a good alternative for patients with keratoconus and for those who failed to respond to other types of lens rehabilitation that results in both successful visual outcome and comfort.
키워드
contact lenseskeratoconusMSD miniscleral contact lensscleral contact lens fittingCOLLAGEN CROSS-LINKINGCORNEAL SENSITIVITYPROGRESSIVE KERATOCONUSTEAR FUNCTIONIN-VIVOINNERVATIONMICROSCOPYSEVERITYINDEXESDISEASE
식별자
- Scopus EID
- 2-s2.0-84983503487
- WoS UID
- 000640424500010



로그인
연구물 목록으로