본문 바로가기

Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations Updated guidelines for reporting parallel group randomized trials

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
MEDICINE96(25) · 2017
피인용
Web of Science 5Scopus 8
FWCI (Scopus)
0.25
JCR IF
JCR 2016 1.804
ISSN
0025-7974

저자

  1. 최윤지제1저자Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Gyeongsangnam-do, South Korea
  2. Min, Sam HongTnTn Hospital, South Korea
  3. Park, Jeong JunDepartment of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seongbuk-gu, Seoul, South Korea
  4. Cho, Jang EunDepartment of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seongbuk-gu, Seoul, South Korea
  5. Yoon, Seung Zhoo교신저자Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seongbuk-gu, Seoul, South Korea
  6. Yoon, Suk MinDepartment of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seongbuk-gu, Seoul, South Korea
  7. Amornyotin, Somchai

초록

Background: For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia machines. Methods: The patients were divided into 11 groups according to the anesthesia machine used (Ohmeda, Excel; Avance; Drager, Cato; and Primus) and the fresh gas flow (FGF) rate (0.5, 1, and 4L/min). The temperature and absolute humidity of the inspired gas in the inspiratory limbs were measured at 5, 10, 15, 30, 45, 60, 75, 90, 105, and 120 minutes in 9 patients scheduled for total thyroidectomy or cervical spine operation in each group. Results: The anesthesia machines of Excel, Avance, Cato, and Primus did not show statistically significant changes in the inspired gas temperatures over time within each group with various FGFs. They, however, showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with low FGF anesthesia (P<.05). The anesthesia machines of Cato and Primus showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with an FGF of 4L/min (P<.05). However, even with low-flow anesthesia, the temperatures and absolute humidities of the inspired gas for all anesthesia machines were lower than the recommended values. Conclusion: There were statistical differences in the provision of humidity among different anesthesia workstations. The Cato and Primus workstations were superior to Excel and Avance. However, even these were unsatisfactory in humans. Therefore, additional devices that provide inspired gases with adequate heat and humidity are needed for those undergoing general anesthetic procedures.

키워드

absolute humidityanesthesia machinehumidificationtemperatureLOW-FLOW ANESTHESIAMOISTURE EXCHANGERINSPIRED GASDRY AIRHEATHUMIDIFICATIONSYSTEM

식별자

Scopus EID
2-s2.0-85021767581
WoS UID
000404116900053