본문 바로가기

Electricity Production by the Application of a Low Voltage DC-DC Boost Converter to a Continuously Operating Flat-Plate Microbial Fuel Cell

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
ENERGIES10(5) · 2017
피인용
Web of Science 17
JCR IF
JCR 2016 2.262
ISSN
1996-1073

저자

  1. 송영은제1저자School of Chemical and Biomolecular Engineering, Pusan National University, Geumjeong-gu, Busan, South Korea
  2. Boghani, Hitesh C.Sustainable Environment Research Centre (SERC), Faculty of Computing, Engineering and Science, University of South Wales, Pontypridd, United Kingdom
  3. Kim, Hong SuckMFC Research and Business Development (R and BD) Center, K-water Institute, Yuseong-Gu, Daejeon, South Korea
  4. Kim, Byung GoonMFC Research and Business Development (R and BD) Center, K-water Institute, Yuseong-Gu, Daejeon, South Korea
  5. 이태호Department of Civil and Environmental Engineering, Pusan National University, Geumjeong-gu, Busan, South Korea
  6. Jeon, Byong-HunDepartment of Natural Resources and Environmental Engineering, Hanyang University, Seoul, South Korea
  7. Premier, Giuliano C.Sustainable Environment Research Centre (SERC), Faculty of Computing, Engineering and Science, University of South Wales, Pontypridd, United Kingdom
  8. 김중래교신저자School of Chemical and Biomolecular Engineering, Pusan National University, Geumjeong-gu, Busan, South Korea

초록

An ultra-low voltage customized DC-DC booster circuit was developed using a LTC3108 converter, and used continuously on a flat-plate microbial fuel cell (FPM) system. The boost converter successfully stepped up the microbial fuel cell (MFC) voltage from similar to 0.5 V to 3.3 and 5.0 V of outputs. The designed circuit and system displayed the dynamic variations of the source FPM as well as the output voltage through the designed three connection points within the booster circuit. The source MFC voltage was interrelated with the booster circuit and its performance, and it adapted to the set points of the booster dynamically. The maximum output power density of the MFC with the DC-DC booster circuit was 8.16 W/m(3) compared to the maximum source FPM input power of 14.27 W/m(3) at 100 W, showing a conversion efficiency of 26-57%, but with a 10-fold higher output than that of the source voltage. The combined LTC3108 with FPM supplied power for electronic devices using synthetic and real domestic wastewater. This report presents a promising strategy for utilizing the electrical energy produced from MFCs, and expands the applicability of bioelectrochemical systems with an improved energy efficiency of the present wastewater treatment system.

키워드

energy efficient wastewater treatmentmicrobial fuel cellpower qualityDC-DC boost converterLTC3108POWER MANAGEMENT-SYSTEMPERFORMANCE EVALUATIONGENERATIONEFFICIENCYREVERSAL