Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY12(5) · pp.855 · 2017
- 피인용
- Web of Science 7Scopus 9
- FWCI (Scopus)
- 0.2
- JCR IF
- JCR 2016 1.863
- ISSN
- 1861-6410
저자
- Park, Jaeyeong제1저자Division of Biomedical Science, Kyungpook National University, Daegu, South Korea
- Kim, Jun-Young교신저자Department of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, South Korea
- Kim, Hyun DeokInstitute of Advanced Convergence Technology, Kyungpook National University, Daegu, South Korea
- Kim, Young CheolInstitute of Advanced Convergence Technology, Kyungpook National University, Daegu, South Korea
- Seo, AnnaInstitute of Advanced Convergence Technology, Kyungpook National University, Daegu, South Korea
- Je, MinkyuSchool of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Mun, Jong UkDepartment of Orthopedic Surgery, Changwon Gyeongsang National University Hospital, Changwon, South Korea
- 김비아Department of Psychology, Pusan National University, Pusan, South Korea
- Park, Il HyungDepartment of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, South Korea
- Kim, Shin-YoonDepartment of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, South Korea
초록
Radiographic measurements using two-dimensional (2D) plain radiographs or planes from computed tomography (CT) scans have several drawbacks, while measurements using images of three-dimensional (3D) reconstructed bone models can provide more consistent anthropometric information. We compared the consistency of results using measurements based on images of 3D reconstructed bone models (3D measurements) with those using planes from CT scans (measurements using 2D slice images). Ninety-six of 561 patients who had undergone deep vein thrombosis-CT between January 2013 and November 2014 were randomly selected. We evaluated measurements using 2D slice images and 3D measurements. The images used for 3D reconstruction of bone models were obtained and measured using and (Materialize, Leuven, Belgium). The mean acetabular inclination, acetabular anteversion and femoral anteversion values on 2D slice images were 42.01, 18.64 and 14.44, respectively, while those using images of 3D reconstructed bone models were 52.80, 14.98 and 17.26. Intra-rater reliabilities for acetabular inclination, acetabular anteversion, and femoral anteversion on 2D slice images were 0.55, 0.81, and 0.85, respectively, while those for 3D measurements were 0.98, 0.99, and 0.98. Inter-rater reliabilities for acetabular inclination, acetabular anteversion and femoral anteversion on 2D slice images were 0.48, 0.86, and 0.84, respectively, while those for 3D measurements were 0.97, 0.99, and 0.97. The differences between the two measurements are explained by the use of different tools. However, more consistent measurements were possible using the images of 3D reconstructed bone models. Therefore, 3D measurement can be a good alternative to measurement using 2D slice images.
키워드
Acetabular orientationFemoral anteversionImages of 3D reconstructed bone models3D measurementsMeasurements using 2D slice imagesTOTAL HIP-ARTHROPLASTYCOMPONENT ORIENTATIONCOMPUTED-TOMOGRAPHYPLAIN ANTEROPOSTERIORSTEM ANTEVERSIONCUP NAVIGATIONVERSIONREPLACEMENTPOPULATIONGENDER
식별자
- Scopus EID
- 2-s2.0-85028263449
- WoS UID
- 000400863100017



로그인
연구물 목록으로