본문 바로가기

Predictive performance of the modified Marsh and Schnider models for propofol in underweight patients undergoing general anaesthesia using target-controlled infusion

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
BRITISH JOURNAL OF ANAESTHESIA118(6) · pp.883 · 2017
피인용
Web of Science 18Scopus 26
FWCI (Scopus)
1.78
JCR IF
JCR 2016 6.238
ISSN
0007-0912

저자

  1. Lee, Y. H.제1저자Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
  2. Choi, G. H.University of Ulsan College of Medicine, Seoul, South Korea
  3. Jung, K. W.Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
  4. 최병현Department of Surgery, Pusan National University Yangsan Hospital, Yangsan, South Korea
  5. Bang, J. Y.Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
  6. Lee, E. K.Department of Statistics, Ewha Womans University, Seoul, South Korea
  7. Choi, B. M.교신저자Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
  8. Noh, G. J.Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea

초록

Background: In our preliminary study, the modified Marsh (M-Marsh) model caused an inadvertent underdosing of propofol in underweight patients. However, the predictive performance of the M-Marsh and Schnider models incorporated in commercially available target-controlled infusion (TCI) pumps was not evaluated in underweight patients. Methods: Thirty underweight patients undergoing elective surgery were randomly allocated to receive propofol via TCI using the M-Marsh or Schnider models. The target effect-site concentrations (Ces) of propofol were, in order, 2.5, 3, 4, 5, 6 and 2 mu g ml(-1). Arterial blood samples were obtained at least 7 min after achieving each pseudo-steady-state. Results: A total of 172 plasma samples were used to determine the predictive performance of both models. The pooled median (95% confidence interval) biases and inaccuracies at a target Ce <= 3 mu g ml(-1) were -22.6 (-28.8 to -12.6) and 31.9 (24.8-36.8) for the M-Marsh model and 9.0 (1.7-16.4) and 28.5 (21.7-32.8) for the Schnider model, respectively. These values at Ce >= 4 mu g ml(-1) were -9.6 (-16.0 to -6.0) and 24.7 (21.1-27.9) for the M-Marsh model and 19.8 (12.9-25.7) and 36.2 (31.4-39.7) for the Schnider model, respectively. Conclusions: The pooled biases and inaccuracies of both models were clinically acceptable. However, the M-Marsh and Schnider models consistently produced negatively and positively biased predictions, respectively, in underweight patients. In particular, the M-Marsh model showed greater inaccuracy at target Ce <= 3 mu g ml(-1) and the Schnider model showed greater inaccuracy at target Ce >= 4 mu g ml(-1). Therefore, it is necessary to develop a new pharmacokinetic model for propofol in underweight patients.

키워드

modelpharmacokineticspropofolunderweightCOMPUTER-CONTROLLED INFUSIONPHARMACOKINETIC MODELUDP-GLUCURONOSYLTRANSFERASESPARAMETER SETSPHARMACODYNAMICSREMIFENTANILDISPOSITIONPOPULATIONCHILDRENDISEASE

식별자

Scopus EID
2-s2.0-85026744394
WoS UID
000402742200012