Predictive performance of the modified Marsh and Schnider models for propofol in underweight patients undergoing general anaesthesia using target-controlled infusion
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- BRITISH JOURNAL OF ANAESTHESIA118(6) · pp.883 · 2017
- 피인용
- Web of Science 18Scopus 26
- FWCI (Scopus)
- 1.78
- JCR IF
- JCR 2016 6.238
- ISSN
- 0007-0912
저자
- Lee, Y. H.제1저자Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
- Choi, G. H.University of Ulsan College of Medicine, Seoul, South Korea
- Jung, K. W.Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
- 최병현Department of Surgery, Pusan National University Yangsan Hospital, Yangsan, South Korea
- Bang, J. Y.Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
- Lee, E. K.Department of Statistics, Ewha Womans University, Seoul, South Korea
- Choi, B. M.교신저자Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
- Noh, G. J.Department of Anaesthesiology and Pain Medicine, Asan Medical Centre, University of Ulsan College of Medicine, Seoul, South Korea
초록
Background: In our preliminary study, the modified Marsh (M-Marsh) model caused an inadvertent underdosing of propofol in underweight patients. However, the predictive performance of the M-Marsh and Schnider models incorporated in commercially available target-controlled infusion (TCI) pumps was not evaluated in underweight patients. Methods: Thirty underweight patients undergoing elective surgery were randomly allocated to receive propofol via TCI using the M-Marsh or Schnider models. The target effect-site concentrations (Ces) of propofol were, in order, 2.5, 3, 4, 5, 6 and 2 mu g ml(-1). Arterial blood samples were obtained at least 7 min after achieving each pseudo-steady-state. Results: A total of 172 plasma samples were used to determine the predictive performance of both models. The pooled median (95% confidence interval) biases and inaccuracies at a target Ce <= 3 mu g ml(-1) were -22.6 (-28.8 to -12.6) and 31.9 (24.8-36.8) for the M-Marsh model and 9.0 (1.7-16.4) and 28.5 (21.7-32.8) for the Schnider model, respectively. These values at Ce >= 4 mu g ml(-1) were -9.6 (-16.0 to -6.0) and 24.7 (21.1-27.9) for the M-Marsh model and 19.8 (12.9-25.7) and 36.2 (31.4-39.7) for the Schnider model, respectively. Conclusions: The pooled biases and inaccuracies of both models were clinically acceptable. However, the M-Marsh and Schnider models consistently produced negatively and positively biased predictions, respectively, in underweight patients. In particular, the M-Marsh model showed greater inaccuracy at target Ce <= 3 mu g ml(-1) and the Schnider model showed greater inaccuracy at target Ce >= 4 mu g ml(-1). Therefore, it is necessary to develop a new pharmacokinetic model for propofol in underweight patients.
키워드
modelpharmacokineticspropofolunderweightCOMPUTER-CONTROLLED INFUSIONPHARMACOKINETIC MODELUDP-GLUCURONOSYLTRANSFERASESPARAMETER SETSPHARMACODYNAMICSREMIFENTANILDISPOSITIONPOPULATIONCHILDRENDISEASE