본문 바로가기

The colorimetric assay of diamine oxidase activity with high sensitivity based on calixarene derivative-capped gold nanoparticles

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
ANALYTICAL METHODS9(14) · pp.2153 · 2017
피인용
Web of Science 12Scopus 13
FWCI (Scopus)
0.57
JCR IF
JCR 2016 1.9
ISSN
1759-9660

저자

  1. Wu, Beiping제1저자Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, China
  2. Zou, FeiCenter for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, China
  3. Wang, XingxinCenter for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, China
  4. 고광락Institute of General Education, Pusan National University, Busan, South Korea
  5. Wang, Keming교신저자Department of Oncology, Second Affiliated Hospital of Nanjing Medical University, Nanjing, China
  6. Chen, HongxiaCenter for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, China

초록

Diamine oxidase (DAO) is involved in regulating ingested or endogenous histamine, several types of human cancer, and the cell mass during embryonic development. Furthermore, DAO is a potential indicator of intestinal mucosa damage in inflammatory and neoplastic diseases or after chemotherapy. Therefore, developing a biosensor is urgently needed to assay DAO activity. In this work, a simple but sensitive colorimetric biosensor is developed for DAO assay and inhibitor screening. The biosensor is based on host-guest interactions between the amine group on the terminal of 1,6-hexanediamine (HMD) and p-sulfonatocalix[ 6] arene (pSC(6)). These interactions may aggregate pSC6 modified gold nanoparticles (AuNPs) and induce the corresponding color change of the test solution. Specifically, AuNP aggregation is affected because coordination reactivity does not exist between oxidized HMD and pSC6 during HMD oxidation by DAO. Therefore, a simple colorimetric method with high sensitivity for the assay of DAO activity is proposed. A linear relationship is presented under optimized experimental conditions in a range of 0.15 mU mL(-1) to 4.5 mU mL(-1) with the lowest detection limit of 0.062 mU mL(-1). Moreover, the inhibition effect of guanidine on DAO activity is tested with the IC50 value of 2.4 mM using the proposed biosensor. Therefore, this biosensor has great potential not only for the detection of DAO activity but also for inhibitor screening in future.

키워드

HISTAMINASEPROTEINMARKERSENSORRECOGNITIONMOLECULESCARCINOMAACID

식별자

Scopus EID
2-s2.0-85017285692
WoS UID
000399913600003