본문 바로가기

Dynamic shear strength of unreinforced and Hairpin-reinforced cast-in-place anchors using shaking table tests

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
STRUCTURAL ENGINEERING AND MECHANICS58(1) · pp.39 · 2016
피인용
Web of Science 1KCI 0
JCR IF
JCR 2015 1.021
ISSN
1225-4568

저자

  1. 김동현제1저자부산대학교
  2. 박용명교신저자부산대학교
  3. 강충현부산대학교
  4. 이종한대구대학교

초록

Since the publication of ACI 318-02, the concrete capacity design (CCD) method has been used to determine the resistance of unreinforced concrete anchors. The regulation of steel-reinforced anchors was proposed in ACI 318-08. Until ACI 318-08, the shear resistance of concrete breakout for an unreinforced anchor during an earthquake was reduced to 75% of the static shear strength, but this reduction has been eliminated since ACI 318-11. In addition, the resistance of a hairpin-reinforced anchor was calculated using only the strength of the steel, and a regulation on the dynamic strength was not given for reinforced anchors. In this study, shaking table tests were performed to evaluate the dynamic shear strength of unreinforced and hairpin-reinforced cast-in-place (CIP) anchors during earthquakes. The anchors used in this study were 30 mm in diameter, with edge distances of 150 mm and embedment depths of 240 mm. The diameter of the hairpin steel was 10 mm. Shaking table tests were carried out on two specimens using the artificial earthquake, based on the United States Nuclear Regulatory Commission (US NRC)'s Regulatory Guide 1.60, and the Northridge earthquake. The experimental results were compared to the current ACI 318 and ETAG 001 design codes.

키워드

cast-in-place anchorunreinforced anchorhairpin-reinforced anchordynamic shear strengthshaking table tests

식별자

WoS UID
000377144400003
KCI
ART002090665