본문 바로가기

Factors associated with clinical failure of self-expandable metal stent for malignant gastroduodenal obstruction.

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY51(1) · pp.103 · 2016
피인용
Web of Science 14
JCR IF
JCR 2015 2.199
ISSN
0036-5521

저자

  1. 신영신제1저자Department of Internal Medicine, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  2. 최철웅교신저자Department of Internal Medicine, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  3. 강대환Department of Internal Medicine, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  4. 김형욱Department of Internal Medicine, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  5. 김수진Department of Internal Medicine, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  6. 조몽Department of Internal Medicine, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  7. 황순휘Department of Surgery, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
  8. 이시학Department of Surgery, Pusan Natl. Univ. Sch. of Med. and Res. Inst. for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea

초록

Objective. Endoscopic self-expandable metal stent (SEMS) placement has emerged as an effective palliative treatment for inoperable malignant gastric outlet obstruction (GOO). In spite of successful stent placement, some patients complain of ongoing dysphagia and vomiting. Most reported data on SEMS to date are about technical success of different types of stents and low complication rates. The aim of this study was to evaluate the associated factors of clinical failure after endoscopic SEMS placement for inoperable malignant GOO. Methods. A total 122 patients who underwent successful endoscopic SEMS placement for malignant GOO in an academic referral center were included in the analyses. We retrospectively evaluated variables associated with clinical outcomes after successful SEMS placement. Results. The clinical success rate was 81.1%. The common causes of GOO were pancreatic (39%) and gastric cancers (32%). The mean length of the stents (+/- standard deviation) was 10.06 +/- 2.42 cm. Multivariate analysis revealed that gallbladder cancer (p = 0.016, OR 6.486, 95% CI, 1.509-59.655), poor performance status (ECOG >= 3) (p = 0.001, OR 10.200, 95% CI, 2.435-42.721), the presence of carcinomatosis peritonei (p < 0.001, OR 35.714, 95% CI, 5.556-250.000) and the failure of endoscope passage (p = 0.039, OR 6.945, 95% CI, 1.101-43.818) Conclusion. Our results suggest that gallbladder cancer, poor performance status (ECOG >= 3) and the presence of carcinomatosis peritonei related with clinical failure of palliative SEMS placement.

키워드

stentgastric outlet obstructionstomach cancerpancreatic cancerGASTRIC OUTLET OBSTRUCTIONMULTICENTERPALLIATIONCARCINOMATOSISSTRICTURESPLACEMENTOUTCOMESTRIAL

식별자

WoS UID
000373621900016