본문 바로가기

Discrimination of Basal Cell Carcinoma from Normal Skin Tissue Using High-Resolution Magic Angle Spinning H-1 NMR Spectroscopy

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
PLOS ONE11(3) · 2016
피인용
Web of Science 20
JCR IF
JCR 2015 3.057
ISSN
1932-6203

저자

  1. Mun, Je-Ho제1저자Department of Dermatology, Seoul National University College of Medicine, Seoul, South Korea
  2. 이헌호Department of Chemistry, Centerfor Proteome Biophysics and Chemistry, Institute for Functional Materials, Pusan National University, Busan, South Korea
  3. 윤다혜Department of Chemistry, Centerfor Proteome Biophysics and Chemistry, Institute for Functional Materials, Pusan National University, Busan, South Korea
  4. 김병수Department of Dermatology, Pusan National University School of Medicine, Busan, South Korea
  5. 김문범Department of Dermatology, Pusan National University School of Medicine, Busan, South Korea
  6. 김석만교신저자Department of Chemistry, Centerfor Proteome Biophysics and Chemistry, Institute for Functional Materials, Pusan National University, Busan, South Korea

초록

High-resolution magic angle spinning nuclear magnetic resonance (HR-MAS NMR) spectroscopy is a useful tool for investigating the metabolism of various cancers. Basal cell carcinoma (BCC) is the most common skin cancer. However, to our knowledge, data on metabolic profiling of BCC have not been reported in the literature. The objective of the present study was to investigate the metabolic profiling of cutaneous BCC using HR-MAS H-1 NMR spectroscopy. HR-MAS H-1 NMR spectroscopy was used to analyze the metabolite profile and metabolite intensity of histopathologically confirmed BCC tissues and normal skin tissue (NST) samples. The metabolic intensity normalized to the total spectral intensities in BCC and NST was compared, and multivariate analysis was performed with orthogonal partial least-squares discriminant analysis (OPLS-DA). P values < 0.05 were considered statistically significant. Univariate analysis revealed 9 metabolites that showed statistically significant difference between BCC and NST. In multivariate analysis, the OPLS-DA models built with the HR-MAS NMR metabolic profiles revealed a clear separation of BCC from NST. The receiver operating characteristic curve generated from the results revealed an excellent discrimination of BCC from NST with an area under the curve (AUC) value of 0.961. The present study demonstrated that the metabolite profile and metabolite intensity differ between BCC and NST, and that HR-MAS H-1 NMR spectroscopy can be a valuable tool in the diagnosis of BCC.

키워드

MAGNETIC-RESONANCE-SPECTROSCOPYMULTIVARIATE DATA-ANALYSISMAS MR SPECTROSCOPYMETABOLIC CHARACTERIZATIONPROSTATE-CANCERNMRBREASTTUMORSH-1QUANTIFICATION

식별자

WoS UID
000371724200082