본문 바로가기

The First Application of the Two-Dimensional Scanning Videokymography in Excised Canine Larynx Model

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q1
저널
JOURNAL OF VOICE30(1) · pp.1 · 2016
피인용
Web of Science 8
JCR IF
JCR 2015 1.113
ISSN
0892-1997

저자

  1. 왕수건제1저자Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Seo-Gu, Busan, South Korea
  2. 박희준Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Seo-Gu, Busan, South Korea
  3. 조재근Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Seo-Gu, Busan, South Korea
  4. 장전엽Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Seo-Gu, Busan, South Korea
  5. 이원용Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University, Yangsan Hospital, Yangsan, Kyeongnam, South Korea
  6. 이병주Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Seo-Gu, Busan, South Korea
  7. 이진춘Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University, Yangsan Hospital, Yangsan, Kyeongnam, South Korea
  8. 차원재교신저자Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Seo-Gu, Busan, South Korea

초록

Objective. Evaluation of the vibratory pattern of vocal folds is of paramount importance to diagnose vocal fold disorders. Currently, laryngeal videokymography (VKG) and digital kymography from high-speed videolaryngoscopy are the available techniques for studying aperiodic vibrations of vocal folds. But VKG has the fundamental limitation that only linear portion of the vocal fold mucosa can be visualized. Digital kymography has the disadvantages of no immediate feedback during examination, considerable waiting time before kymographic visualization, recoding duration limited to seconds, and extreme demands on storage space. We developed a new system-two-dimensional (2D) scanning VKG-for evaluation of the vibratory pattern of vocal folds, and the method provided a possible alternative with its advantages and disadvantages. Thus, we aimed to evaluate the feasibility of the new device for the vocal fold vibration in excised canine larynx model. Methods. The vibrating pattern for vocal folds was evaluated using high-speed videolaryngoscopic and 2D scanning videokymographic system in the excised canine larynx model. Results. The images of canine vocal folds were captured with high-speed videolaryngoscopic system and converted to the kymographic images using the software. The kymographic image acquired by 2D scanning VKG was comparable with multi-line digital kymography at multiple locations. Conclusions. The vocal fold vibration could be evaluated in the excised canine larynx model using 2D scanning VKG. And this new device is expected to be a promising tool to evaluate the vocal fold vibration for clinical practice and voice research.

키워드

VideokymographyVocal foldVibrationCanine larynxHigh-speed video systemVOCAL FOLD VIBRATIONKYMOGRAPHY

식별자

WoS UID
000367482200001