Influence of wavelength-shifting films on multianode PMTs with UV-extended windows
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT783 · pp.43 · 2015
- 피인용
- Web of Science 11
- JCR IF
- JCR 2014 1.216
- ISSN
- 0168-9002
저자
- Adamczewski-Musch, J.제1저자GSI Helmholtzzentrum Schwerionenforschung GmbH, GE
- Becker, K. -H.Univ Wuppertal, Dept Phys, GE
- Belogurov, S.SSC RF ITEP, RU
- Boldyreva, N.PNPI RAS Gatchina, RU
- Chernogorov, A.SSC RF ITEP, RU
- Deveaux, C.Univ Giessen, Inst Appl Phys, Inst Phys 2, GE
- Dobyrn, V.PNPI RAS Gatchina, RU
- Duerr, M.교신저자Univ Giessen, Inst Appl Phys, Inst Phys 2, GE
- 엄종식부산대학교, 자연과학대학, 물리학과, KO
- Eschke, J.GSI Helmholtzzentrum Schwerionenforschung GmbH, GE
- Hoehne, C.Univ Giessen, Inst Appl Phys, Inst Phys 2, GE
- Kampert, K. -H.Univ Wuppertal, Dept Phys, GE
- Kleipa, V.GSI Helmholtzzentrum Schwerionenforschung GmbH, GE
- Kochenda, L.PNPI RAS Gatchina, RU
- Kolb, B.GSI Helmholtzzentrum Schwerionenforschung GmbH, GE
- Kopfer, J.교신저자Univ Wuppertal, Dept Phys, GE
- Kravtsov, P.PNPI RAS Gatchina, RU
- Lebedev, S.Univ Giessen, Inst Appl Phys, Inst Phys 2, GE
- Lebedeva, E.Univ Giessen, Inst Appl Phys, Inst Phys 2, GE
- Leonova, E.PNPI RAS Gatchina, RU
- Linev, S.GSI Helmholtzzentrum Schwerionenforschung GmbH, GE
- Mahmoud, T.Univ Giessen, Inst Appl Phys, Inst Phys 2, GE
- Michel, J.Univ Frankfurt, Inst Kernphys, GE
- Miftakhov, N.PNPI RAS Gatchina, RU
- 남용호부산대학교, 자연과학대학, 물리학과, KO
- Niebur, W.GSI Helmholtzzentrum Schwerionenforschung GmbH, GE
- 오근수부산대학교, 자연과학대학, 물리학과, KO
- Ovcharenko, E.SSC RF ITEP, RU
- Pauly, C.Univ Wuppertal, Dept Phys, GE
- Pouryamout, J.Univ Wuppertal, Dept Phys, GE
- 송지혜부산대학교, 자연과학대학, 물리학과, KO
- 이준규부산대학교, 자연과학대학, 물리학과, KO
- 유인권부산대학교, 자연과학대학, 물리학과, KO
초록
Wavelength-shifting (WLS) films were applied on UV-extended front windows of multianode photo-multiplier tubes (MAPMTs) in order to increase the sensitivity of the MAPMTs at shorter wavelengths. The WLS material contained p-Terphenyl as photoactive component, which absorbs shorter wavelength photons ( < 300 nm) and re-emits fluorescence photons around 350 nm, i.e., at the maximum of the PMT's sensitivity. The films were applied by means of dip-coating and the film performance was studied with respect to quantum efficiency, film homogeneity, and crosstalk on the MAPMT's. Using WLS-film-covered MAPMTs in a gaseous Ring Imaging Cherenkov detector, the number of detected photoelectrons per ring increased by up to 21% in an in-beam test. (C) 2015 Elsevier B.V. All rights reserved.
키워드
Wavelength-shifting filmsDip-coatingMultianode PMTQuantum efficiencyCherenkov detectorRICHRICH DETECTORCBMPHOTOMULTIPLIERSLIGHT
식별자
- WoS UID
- 000352142200007



로그인
연구물 목록으로