본문 바로가기

Sepsis affects most routine and cell population data (CPD) obtained using the Sysmex XN-2000 blood cell analyzer: neutrophil-related CPD NE-SFL and NE-WY provide useful information for detecting sepsis

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
피인용
Web of Science 77
JCR IF
JCR 2014 1.819
ISSN
1751-5521

저자

  1. 박상혁제1저자Department of Laboratory Medicine, Pusan National University School of Medicine, Pusan National University Hospital, Busan, South Korea
  2. Park, C. J.교신저자Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  3. Lee, B. R.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  4. Nam, K. S.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  5. Kim, M. J.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  6. Han, M. Y.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  7. Kim, Y. J.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  8. Cho, Y. U.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
  9. Jang, S.Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea

초록

IntroductionThe Sysmex XN-2000 analyzer can assess 36 routine and 57 cell population data (CPD) items. In this study, we evaluated these items as sepsis biomarkers. MethodsWe enrolled 280 normal control (NC) and 130 sepsis patients. The sepsis patients were classified as uncomplicated or complicated sepsis. Routine and CPD items were determined, and the results were compared at between the NC and sepsis groups, uncomplicated and complicated sepsis groups, and survivors and nonsurvivors. ResultsFor the detection of sepsis, CPD items NE-SFL [defined as the fluorescent light intensity of the neutrophil area on the WDF (white blood cell differential) scattergram] and NE-WY (defined as the fluorescent light distribution width of the neutrophil area on the WDF scattergram) showed comparative or higher AUC of 0.909 and 0.905, respectively, when compared with routine items such as hematocrit, hemoglobin, RBC, RDW, immature granulocytes count, lymphocytes count, and neutrophils count. For the discrimination of sepsis severity, only platelet-related items showed higher AUC (0.723 - 0.748) than lactic acid (0.695). For the prediction of 28-day mortality, only CV and SD of RDW showed higher AUC (0.766 and 0.732 each) than lactic acid (0.712). ConclusionsSepsis patients demonstrated significant changes in routine and CPD items related to RBC, neutrophils, lymphocytes, and platelets when compared to NCs. Increase in CPD items NE-SFL and NE-WY, which may indicate neutrophil immaturity or activation, could be useful for the detection of sepsis patients, in conjunction with currently used surrogate sepsis biomarkers. However, these items did not efficiently contribute to the discrimination of sepsis severity or predict mortality.

키워드

SepsisSysmex XN-2000neutrophilcell population dataNE-SFLNE-WYCRITICALLY-ILL PATIENTSMARKERINDEX

식별자

WoS UID
000351355000018