본문 바로가기

Highly sensitive detection of epidermal growth factor receptor expression levels using a capacitance sensor

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SENSORS AND ACTUATORS B-CHEMICAL209 · pp.438 · 2015
피인용
Web of Science 14
JCR IF
JCR 2014 4.097
ISSN
0925-4005

저자

  1. 신동명제1저자Department of Nanomaterials Engineering, BK21 Plus Nanoconvergence Technology Division, Pusan National University (PNU), Miryang, South Korea
  2. 신용철Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
  3. 이종호Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
  4. 김태현Department of Nanomechatronics Engineering, Pusan National University (PNU), Miryang, South Korea
  5. 한동욱Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
  6. 김종만Department of Nanomechatronics Engineering, Pusan National University (PNU), Miryang, South Korea
  7. 김형국Department of Nanomaterials Engineering, BK21 Plus Nanoconvergence Technology Division, Pusan National University (PNU), Miryang, South Korea
  8. 김규정교신저자Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
  9. 황윤회Department of Nanomaterials Engineering, BK21 Plus Nanoconvergence Technology Division, Pusan National University (PNU), Miryang, South Korea

초록

We developed a capacitance sensor with parallel plate geometry to measure epithermal growth factor receptor (EGFR) expression levels on cell membrane in real-time. We first proved correlations between capacitance changes and cell numbers settled down between electrodes, and then observed capacitance changes elicited by interactions between EGFR on membrane and EGF proteins in real time. Consequently, we confirmed that the EGFR expression levels of varied typed cells were successfully quantified. This approach can effectively distinguish differences of EGFR levels of cancer cells and normal cells in real-time. Also, up to 600% sensitivity enhancements and around 2.2 h on average sensing time saving were achieved by using the capacitance sensor over a conventional immunoassay technique. Such a capacitance biosensor can be extended to broad fields where the receptor-antibody reactions, the receptor-virus reactions or DNA hybridizations are involved. (C) 2014 Elsevier B.V. All rights reserved.

키워드

Capacitance biosensorReceptor expression levelEpithermal growth factorFibroblastic cellsOsteoblastic cellsRESONANCE ENERGY-TRANSFERCELL LUNG-CANCERLIVING CELLSTUMOR-MARKERIN-VITROEGFR EXPRESSIONFACTOR-ALPHACARCINOMAMETASTASISSERUM

식별자

WoS UID
000349082200057