Highly sensitive detection of epidermal growth factor receptor expression levels using a capacitance sensor
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- SENSORS AND ACTUATORS B-CHEMICAL209 · pp.438 · 2015
- 피인용
- Web of Science 14
- JCR IF
- JCR 2014 4.097
- ISSN
- 0925-4005
저자
- 신동명제1저자Department of Nanomaterials Engineering, BK21 Plus Nanoconvergence Technology Division, Pusan National University (PNU), Miryang, South Korea
- 신용철Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
- 이종호Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
- 김태현Department of Nanomechatronics Engineering, Pusan National University (PNU), Miryang, South Korea
- 한동욱Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
- 김종만Department of Nanomechatronics Engineering, Pusan National University (PNU), Miryang, South Korea
- 김형국Department of Nanomaterials Engineering, BK21 Plus Nanoconvergence Technology Division, Pusan National University (PNU), Miryang, South Korea
- 김규정교신저자Department of Cogno-Mechatronics Engineering, Pusan National University (PNU), Busan, South Korea
- 황윤회Department of Nanomaterials Engineering, BK21 Plus Nanoconvergence Technology Division, Pusan National University (PNU), Miryang, South Korea
초록
We developed a capacitance sensor with parallel plate geometry to measure epithermal growth factor receptor (EGFR) expression levels on cell membrane in real-time. We first proved correlations between capacitance changes and cell numbers settled down between electrodes, and then observed capacitance changes elicited by interactions between EGFR on membrane and EGF proteins in real time. Consequently, we confirmed that the EGFR expression levels of varied typed cells were successfully quantified. This approach can effectively distinguish differences of EGFR levels of cancer cells and normal cells in real-time. Also, up to 600% sensitivity enhancements and around 2.2 h on average sensing time saving were achieved by using the capacitance sensor over a conventional immunoassay technique. Such a capacitance biosensor can be extended to broad fields where the receptor-antibody reactions, the receptor-virus reactions or DNA hybridizations are involved. (C) 2014 Elsevier B.V. All rights reserved.
키워드
Capacitance biosensorReceptor expression levelEpithermal growth factorFibroblastic cellsOsteoblastic cellsRESONANCE ENERGY-TRANSFERCELL LUNG-CANCERLIVING CELLSTUMOR-MARKERIN-VITROEGFR EXPRESSIONFACTOR-ALPHACARCINOMAMETASTASISSERUM
식별자
- WoS UID
- 000349082200057



로그인
연구물 목록으로