본문 바로가기

Determination of tolerances of mirror displacement and radiator gas impurity for the CBM RICH detector

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
피인용
Web of Science 4
JCR IF
JCR 2013 1.316
ISSN
0168-9002

저자

  1. Adamczewski-Musch, J.제1저자GSI Darmstadt, GE
  2. Becker, K. -H.Univ Wuppertal, GE
  3. Belogurov, S.Kurchatov Inst, RU
  4. Boldyreva, N.PNPI Gatchina, RU
  5. Chernogorov, A.Kurchatov Inst, RU
  6. Deveaux, C.Univ Giessen, GE
  7. Dobyrn, V.PNPI Gatchina, RU
  8. Duerr, M.Univ Giessen, GE
  9. 엄종식부산대학교, 자연과학대학, 물리학과, KO
  10. Eschke, J.GSI Darmstadt, GE
  11. Hoehne, C.Univ Giessen, GE
  12. Kampert, K. -H.Univ Wuppertal, GE
  13. Kleipa, V.GSI Darmstadt, GE
  14. Kochenda, L.GSI Darmstadt, GE
  15. Kolb, B.GSI Darmstadt, GE
  16. Kopfer, J.Univ Wuppertal, GE
  17. Kravtsov, P.PNPI Gatchina, RU
  18. Lebedev, S.Univ Giessen, GE
  19. Lebedeva, E.Univ Giessen, GE
  20. Leonova, E.PNPI Gatchina, RU
  21. Linev, S.GSI Darmstadt, GE
  22. Mahmoud, T.교신저자Univ Giessen, GE
  23. Michel, J.GSI Darmstadt, GE
  24. Miftakhov, N.PNPI Gatchina, RU
  25. 남용호부산대학교, 자연과학대학, 물리학과, KO
  26. Niebur, W.GSI Darmstadt, GE
  27. 오근수부산대학교, 자연과학대학, 물리학과, KO
  28. Ovcharenko, E.Kurchatov Inst, RU
  29. Pauly, C.Univ Wuppertal, GE
  30. Pouryamout, J.Univ Wuppertal, GE
  31. 송지혜부산대학교, 자연과학대학, 물리학과, KO
  32. 이준규부산대학교, 자연과학대학, 물리학과, KO
  33. 유인권부산대학교, 자연과학대학, 물리학과, KO
저자 45명 모두 보기

초록

The CBM experiment at the future FAIR facility will explore nuclear matter at high net-baryon densities. One of the key observables is di-leptons as they penetrate the created matter without further strong interactions. A gaseous RICH detector in a standard projective geometry using spherical mirrors is one of two detector elements for the required electron identification. The mirror system consists of about 72 trapezoidal mirror tiles. Any misalignment between the tiles relative to the nominal common spherical surface leads to reduction of the reconstruction efficiency of Cherenkov rings and deterioration of their resolution. To determine tolerances in mirror misalignment extensive simulation and measurement studies were carried out. Pure CO2 will be used as radiator gas. Gas contamination, mainly moisture and Oxygen, reduces the number of detected photons per ring and worsens the quality of reconstructed Cherenkov rings. Therefore a study was carried out to determine tolerances in radiator gas contamination. (C) 2014 Elsevier B.V. All rights reserved,

키워드

CBM RICH detectorMirror displacementGas contamination

식별자

WoS UID
000344622200052