본문 바로가기

Determination of irinotecan and its metabolite SN-38 in rabbit plasma and tumors using a validated method of tandem mass spectrometry coupled with liquid chromatography

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q2
피인용
Web of Science 13
JCR IF
JCR 2013 2.694
ISSN
1570-0232

저자

  1. Park, Dae J.제1저자교신저자Department of Clinical Pharmacology, College of Medicine, Kosin University, South Korea
  2. Won, Jun H.Department of Clinical Pharmacology, College of Medicine, Kosin University, South Korea
  3. Cho, A. R.Department of Clinical Pharmacology, College of Medicine, Kosin University, South Korea
  4. Yun, Hye J.Department of Clinical Pharmacology, College of Medicine, Kosin University, South Korea
  5. Heo, Jeong H.Department of Molecular Biology and Immunology, College of Medicine, Kosin University, South Korea
  6. 황태호Department of Clinical Pharmacology, Pusan National University, South Korea
  7. Lee, Dae H.Department of Clinical Pharmacology, College of Medicine, Kosin University, South Korea
  8. Kim, Woo M.Department of Clinical Pharmacology, College of Medicine, Kosin University, South Korea

초록

New tandem mass spectrometric method coupled with liquid chromatography (LC-MS/MS) has been developed to determine the total concentration of camptothecin derivatives (irinotecan and SN-38) regardless of inter-conversion phenomenon between carboxylate and lactone forms. At first, all sample solutions were acidified for 1 h in order to completely convert CPT derivatives into their lactone forms and then CPT derivatives were extracted with organic solution containing diethyl ether and ethyl acetate (2:1, v/v) just after alkalization in the range pH 8.0-8.5 in acid-treated solutions. Analytes were separated on a reverse phase C-18 column (150 x 2.1 mm) and eluted isocratically with a mobile phase which consisted of acetonitrile-methanol-buffer (0.1% formic acid, 5 mM ammonium formate) (3:4:3, v/v). CPT derivatives were monitored by tandem mass spectrometry in electrospay-positive ionization and multiple reaction mode programmed to the following transitions (m/z): '587.6 -> 167.2' of CPT-11, '393.6 -> 349.3' of SN-38 and '349.4 -> 305.2' of CPT. The method was validated to have the proper linearity (r(2) > 0.99) over the range of 5-1000 ng/ml of CPT-11 and 1-250 ng/ml of SN-38 with good accuracy (89.8-114.3%) and precision (less than 10%). In all stability tests, concentration of CP1-11 and SN-38 had been left in the acceptable range of 88.8-110.7% when sample solutions were acidified before determination of CPT derivatives. Newly developed LC-MS/MS method was suitable for the determination of CPT derivatives of both rabbit plasma and tumor tissues in the pharmacokinetic study. (C) 2014 Elsevier B.V. All rights reserved.

키워드

lrinotecanSN-38CamptothecinRabbitVX2 tumorLC-MS/MS7-ETHYL-10-HYDROXYCAMPTOTHECIN SN-38QUANTITATIVE-DETERMINATIONMOUSE PLASMACAMPTOTHECINCPT-11LACTONECANCERFORMSASSAYCARBOXYLATE

식별자

WoS UID
000338406800019