본문 바로가기

Influence of the implant-abutment connection design and diameter on the screw joint stability

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
JOURNAL OF ADVANCED PROSTHODONTICS6(2) · pp.126 · 2014
피인용
Web of Science 46KCI 4
JCR IF
JCR 2013 0.631
ISSN
2005-7806

저자

  1. 신현모제1저자부산대학교
  2. 허중보부산대학교
  3. 윤미정부산대학교
  4. 전영찬부산대학교
  5. Brian Myung ChangCleveland Clinic, Cleveland, OH, USA
  6. 정창모교신저자부산대학교

초록

PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone Were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney test as post-hoc test (alpha=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss fates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

키워드

Postload removal torque valueExternal butt joint connectionInternal connectionPlatform switchingMULTICENTER RETROSPECTIVE ANALYSISDYNAMIC FATIGUE PROPERTIESSINGLE-TOOTH REPLACEMENTSCRESTAL BONE LEVELSDENTAL IMPLANTSSYSTEMCOMPONENTSINTERFACE

식별자

WoS UID
000335545800009
KCI
ART001869284