Biomechanical assessment of a novel bone lengthening plate system - A cadaveric study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- CLINICAL BIOMECHANICS28(2) · pp.232 · 2013
- 피인용
- Web of Science 0
- JCR IF
- JCR 2012 1.869
- ISSN
- 0268-0033
저자
- 정태곤제1저자Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, South Korea
- Suh, Seung WooScoliosis Research Institute, Department of Orthopedics, Korea University Guro Hospital, South Korea
- Lee, Sung JaeDepartment of Biomedical Engineering, Inje University, South Korea
- Kim, BongjuCenter for Innovation in Immunoregulative Technology and Therapeutics, Kyoto University Graduate School of Medicine, Japan
- 한동욱교신저자Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, South Korea
- Yang, Jae HyukScoliosis Research Institute, Department of Orthopedics, Korea University Guro Hospital, South Korea
초록
Background: Although many types of external fixators have been developed for distraction osteogenesis, all have some drawbacks. We recently developed a novel bone lengthening plate to overcome these problems. The purpose of this study is to conduct biomechanical analyses using cadavers to assess the stability of the bone lengthening plate in relation to distraction length and femoral bone mineral density. Methods: We used human cadaveric femurs (n=18) to assess the effects of distraction length and bone mineral density on the biomechanical stability of the bone lengthening plate. After establishing control (n = 6, 0 mm lengthening) and experimental groups (n = 12, 30 mm lengthening), we measured biomechanical stability (structural stiffness, ultimate load, and displacement) under a compressive load. The experimental group was subdivided into a group with normal bone mineral density (n=6) and a group with osteoporosis (n=6), and the biomechanical stability of these groups was compared. Finding: Structural stiffness differed significantly between the control (417.6 N/mm) and combined experimental groups (185.6 N/mm, p = 0.002). Ultimate load also differed significantly between the control (1327.8 N) and combined experimental (331.4 N, p = 0.002) groups. Bone mineral density was unrelated to structural stiffness (p=0.204), ultimate load (0.876), or displacement (0.344). In all cases, failure of the bone lengthening plate occurred at the longitudinal connectors, such as the connecting columns between the upper and lower plates, and the lengthening shaft of the bone lengthening plate. Interpretation: The biomechanical stability of the bone lengthening plate was affected by the lengthening length but not by bone mineral density. In addition, biomechanical stability during lengthening was most strongly influenced by the longitudinal connectors. (C) 2012 Elsevier Ltd. All rights reserved.
키워드
FemurBiomechanical stabilityBone lengthening plateBone mineral densityLOCKING COMPRESSION PLATEEXTERNAL FIXATORSMECHANICAL PERFORMANCEILIZAROV TECHNIQUEFIXATIONHYBRIDOSTEOSYNTHESISCORROSIONFRACTURECOMPLICATIONS