Ultrasonographic assessment of breast density
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- BREAST CANCER RESEARCH AND TREATMENT138(3) · pp.851 · 2013
- 피인용
- Web of Science 25
- JCR IF
- JCR 2012 4.469
- ISSN
- 0167-6806
저자
- Kim, Won Hwa제1저자서울대학교, Dept Radiol, KO
- Moon, Woo Kyung교신저자서울대학교, Dept Radiol, KO
- Kim, Seung Ja서울대학교, Boramae Med Ctr, Dept Radiol, KO
- Yi, Ann서울대학교, Boramae Med Ctr, Dept Radiol, KO
- Yun, Bo La서울대학교, Dept Radiol, KO
- Cho, Nariya서울대학교, Dept Radiol, KO
- Chang, Jung Min서울대학교, Dept Radiol, KO
- Koo, Hye Ryoung서울대학교, Dept Radiol, KO
- Kim, Mi Young건국대학교, Dept Radiol, KO
- Bae, Min Sun서울대학교, Dept Radiol, KO
- Lee, Su Hyun서울대학교, Dept Radiol, KO
- 김진유부산대학교, 의과대학, 의학과, KO
- Lee, Eun Hee서울대학교, Dept Radiol, KO
초록
Ultrasonographic (US) assessment of breast density has the potential to provide a nonionizing method. This study was to prospectively evaluate intermodality and interobserver agreements for assessment of breast density between US and mammography. Institutional review board approval was obtained. Forty-one women (mean 52.1 years; range 25-72 years) with variable breast density consented to participate. Eight radiologists blinded to mammographic information performed breast US for all participants and assessed each breast density using four categories based on the proportion of the breast occupied by the fibroglandular tissue. All participants underwent full-field digital mammography and mammographic density was independently assessed by eight radiologists 2 weeks after US using the breast imaging reporting and data system (BI-RADS) 4-category system. Intermodality agreements between US and mammographic assessments and interobserver agreements among radiologists were assessed using kappa statistics (D-0) and intraclass correlation coefficients (ICCs). There was substantial intermodality agreement between the US and mammographic assessments of breast density (D-0 = 0.65 and ICC = 0.80), and 68 % (222/328) of the assessments had exact agreement. When categories were dichotomized into fatty (categories 1 and 2) and dense (categories 3 and 4), 86 % (282/328) of the assessments had exact agreement (D-0 = 0.71). The interobserver agreement for the US assessments of breast density was substantial (average D-0 = 0.63, ICC = 0.82) and not significantly different from that for the mammographic assessments (average D-0 = 0.74, ICC = 0.85) (P = 0.701). US and mammography demonstrated substantial intermodality and interobserver agreement for assessment of breast density.
키워드
BreastUltrasonographyMammographyRisk assessmentReproducibility of resultsCANCER RISKMAMMOGRAPHIC DENSITYPARENCHYMAL PATTERNSPOSTMENOPAUSAL WOMENQUANTITATIVE ASSESSMENTULTRASOUND TOMOGRAPHYOBSERVER AGREEMENTDATA SYSTEMMRIREPRODUCIBILITY
식별자
- WoS UID
- 000317977300019



로그인