Mechanical properties of composite resins light-cured using a blue DPSS laser
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- LASERS IN MEDICAL SCIENCE28(2) · pp.597 · 2013
- 피인용
- Web of Science 15
- JCR IF
- JCR 2012 2.402
- ISSN
- 0268-8921
저자
- 백두만제1저자Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
- 박정길Department of Operative Dentistry, School of Dentistry, Pusan National University, South Korea
- 손성애Department of Operative Dentistry, School of Dentistry, Pusan National University, South Korea
- Ko, Ching-ChangDepartment of Orthodontics, School of Dentistry, University of North Carolina, United States
- Garcia-Godoy, FranklinCollege of Dentistry, University of Tennessee, United States
- 김형일Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
- 권용훈교신저자Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
초록
Lasers have many favorable features as a light source owing to their monochromaticity and coherence. This study examined the mechanical properties of composite resins that were light-cured using a diode-pumped solid state (DPSS) laser. Eight composite resins were light-cured using four different light sources (one quartz-tungsten-halogen (QTH), two light-emitting diodes (LEDs), and one DPSS laser with a wavelength of 473 nm). The light intensity of the DPSS laser and remaining light-curing units were approximately 500 and 900 mW/cm(2), respectively. The microhardness, flexural properties, and compressive properties were evaluated using the Vickers hardness test, three-point bending test, and compression test, respectively. In most cases, the microhardness, flexural properties, and compressive properties of the specimens light-cured using the DPSS laser were similar to those obtained using the other light-curing units. Within the limits of the study, the microhardness, flexural modulus, and compressive strength were linearly correlated with the filler content (in weight percent). The flexural modulus and compressive modulus were also linearly correlated with the microhardness. Even with a much lower light intensity, the DPSS laser with a wavelength of 473 nm can polymerize composite resins and give comparable mechanical properties to those obtained using the other light-curing units.
키워드
DPSS laserComposite resinMicrohardnessFlexural propertiesCompressive propertiesRESTORATIVE MATERIALSDENTAL COMPOSITESCURING UNITSRAMAN-SPECTROSCOPYHARDNESSMICROHARDNESSQTH