본문 바로가기

Prediction of a subcooled boiling flow with advanced two-phase flow models

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
NUCLEAR ENGINEERING AND DESIGN253 · pp.351 · 2012
피인용
Web of Science 132
JCR IF
JCR 2011 0.765
ISSN
0029-5493

저자

  1. 윤병조제1저자교신저자School of Mechanical Engineering, Pusan National University, South Korea
  2. Splawski, AndrewCD-adapco, United Kingdom
  3. Lo, SimonCD-adapco, United Kingdom
  4. Song, Chul-HwaKorea Atomic Energy Research Institute, South Korea

초록

Prediction of bubble size which governs interfacial transfer terms between the two phases is of importance for an accurate prediction of the subcooled boiling flow. In the present work, a mechanistic bubbles size model, S-gamma was examined to enhance the prediction capability of subcooled boiling flows for the CFD (computational fluid dynamics) code. In addition to this, advanced subcooled boiling models such as new wall boiling and two-phase logarithmic wall function models were also applied for an improvement of energy partitioning and two-phase turbulence models, respectively. The benchmark calculation against the DEBORA subcooled boiling data confirms that the S-gamma bubble size model with the two advanced subcooled boiling models shows good prediction results and is applicable to the wide range of flow conditions that are expected in the nominal and postulated accidental conditions of a nuclear power plant. (C) 2011 Elsevier B.V. All rights reserved.

키워드

BUBBLE DETACHMENT DIAMETERSINTERFACIAL AREA TRANSPORTUNIFIED MODELSYSTEMSSIMULATIONANNULUSFORCEPHASE

식별자

WoS UID
000314375700034