본문 바로가기

A Simple Separation Method with a Microfluidic Channel Based on Alternating Current Potential Modulation

문서 유형
연구출판물 · 학술지 논문
등재
Nature IndexSCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ANALYTICAL CHEMISTRY84(22) · pp.9738 · 2012
피인용
Web of Science 25
JCR IF
JCR 2011 5.856
ISSN
0003-2700

저자

  1. 노희복제1저자Department of Chemistry, Institute of BioPhysio Sensor Technology, Pusan National University, South Korea
  2. 산드라 프란잘Department of Chemistry, Institute of BioPhysio Sensor Technology, Pusan National University, South Korea
  3. Kim, You-JeongDepartment of Chemistry, Institute of BioPhysio Sensor Technology, Pusan National University, South Korea
  4. 심윤보교신저자Department of Chemistry, Institute of BioPhysio Sensor Technology, Pusan National University, South Korea

초록

A simple separation and detection system based on an electrochemical potential modulated microchannel (EPMM) device was developed for the first time. The application of alternating current (AC) potential to the microfluidic separation channel walls, which were composed of screen printed carbon electrodes, resulted in the oscillation and fluctuation of analytes and in the formation of a perfect flat flow front. These events resulted in an increase in the effective concentration and in the fine separation of samples. The performance of the EPMM device was examined through the analysis of endocrine disruptors (EDs) and heavy metal ions (HMIs) as model compounds. The analytical parameters that affected the separation and detection of EDs and HMIs were studied in terms of AC amplitude, AC frequency, flow rate, buffer concentration, pH, detection potential, and temperature. The separation efficiency was evaluated through measurements of the theoretical plate number (N), the retention time, and the half-peak width. Linear calibration plots for the detection of EDs and HMIs were obtained between 0.15 and 250.0 nM (detection limit 86.4 +/- 2.9 pM) and between 0.01 and 10.0 nM (detection limit 9.5 +/- 0.3 pM), respectively. The new device was successfully demonstrated with authentic and real samples.

키워드

MICROCHIP CAPILLARY-ELECTROPHORESISLIQUID-PHASE MICROEXTRACTIONFIELD-FLOW FRACTIONATIONON-A-CHIPELECTROCHEMICAL DETECTIONPHENOLIC-COMPOUNDSANALYSIS SYSTEMSCHROMATOGRAPHYINJECTIONPRECONCENTRATION

식별자

WoS UID
000312434800014