본문 바로가기

Fault diagnosis of three-parallel voltage-source converter for a high-power wind turbine

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q2
저널
IET POWER ELECTRONICS5(7) · pp.1058 · 2012
피인용
Web of Science 72
JCR IF
JCR 2011 1.621
ISSN
1755-4535

저자

  1. Ko, Y. -J.제1저자아주대학교, Dept Elect & Comp Engn, KO
  2. Lee, K. -B.아주대학교, Dept Elect & Comp Engn, KO
  3. Lee, D. -C.영남대학교, Dept Elect Engn, KO
  4. 김장목부산대학교, 공과대학, 전기공학과, 전기공학전공, KO

초록

A fault detection method for the switch devices of three-parallel power converters in a wind-turbine system is presented. The proposed method utilises the measured three-phase currents (i(a)(s), i(b)(s), i(c)(s)) that were already used for controlling the converters. Additional current and voltage sensors are thus not necessary. Consequently, this particular feature potentially cuts costs to apply the detection algorithm. The three-phase currents are transformed to a stationary reference frame (i(d)(s), i(q)(s)). This reference frame possesses specific patterns in accordance to the conditions of the switch devices in the converter. Faulty switches can be detected by analysing the obtained pattern and pattern recognition is achieved by a neural network that has a learning capability. The proposed method is primarily able to diagnose an open fault switch in the converter. The reliability of the proposed fault detection method was proved by simulations and experiments using a 10 kW simulator.

키워드

SYSTEM

식별자

WoS UID
000311026200016