Interaction of LED light with coinitiator-containing composite resins: Effect of dual peaks
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- JOURNAL OF DENTISTRY40(10) · pp.836 · 2012
- 피인용
- Web of Science 21
- JCR IF
- JCR 2011 2.947
- ISSN
- 0300-5712
저자
- 심재성제1저자Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
- 설효정Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
- 박정길Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
- Garcia-Godoy, FranklinCollege of Dentistry, University of Tennessee Health Science Center, United States
- 김형일Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
- 권용훈교신저자Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
초록
Objectives: Recently the colour stability of composite resins has been an issue due to the emphasis on the aesthetics of restored teeth. The purpose of the present study was to investigate how dual-peak LED units affect the polymerization of coinitiator-containing composite resins. Materials and methods: Five composite resins [coinitiator-containing: Aelite LS Posterior (AL), Tetric EvoCeram (TE), and Vit-l-escence (VI); only CQ-containing: Grandio (GD) and Filtek Z350 (Z3)] were light cured using four different light-curing units (LCUs). Among them, Bluephase G2 (BP) and G-light (GL) were dual-peak LED LCUs. Microhardness, polymerization shrinkage, flexural, and compressive properties were measured. Results: BP and GL had no consistent effect on the microhardness of AL, TE, and VI on the top and bottom surfaces of resin specimens. Among the specimens, AL and VI showed the least (9.86-10.41 mu m) and greatest (17.58-19.21 mu m) polymerization shrinkage, respectively. However, the effect of BP and GL on the shrinkage of specimens was not consistent. Among the specimens, GD showed the greatest flexural properties [strength (FS) and modulus (FM)] and TE showed the lowest flexural and compressive properties [strength (CS) and modulus (CM)]. In same resin product, maximum FS and CS differences due to the different LCUs were 10.321.0% and 3.6-9.2%, respectively. Furthermore, the influences of BP and GL on FS and CS were not consistent. Conclusion: The tested dual-peak LED LCUs had no consistent synergic effect on the polymerization of coinitiator-containing composite resins as compared with QTH and single-peak LED LCUs. Clinical significance: The dual-peak LED LCUs achieve a similar degree of polymerization in coinitiator-composite resins as QTH and single-peak LED LCUs did. Choice of LCU does not appear to be a determinant of the light curing of coinitiator-composite resins. (c) 2012 Elsevier Ltd. All rights reserved.
키워드
CoinitiatorDual-peak LEDPolymerizationCURING LIGHTSMECHANICAL-PROPERTIESTEMPERATURE RISEDENTAL SCHOOLSHALOGEN LAMPCONVERSIONUNITSPOLYMERIZATIONPOLYWAVEHARDNESS
식별자
- WoS UID
- 000308178400008



로그인
연구물 목록으로