Seismic response of base isolating systems with U-shaped hysteretic dampers

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q3Scopus Q3
피인용
Web of Science 37KCI 3
JCR IF
JCR 2011 0.426
ISSN
1598-2351

저자

  1. 오상훈제1저자부산대학교
  2. 송성훈부산대학교
  3. 이상호부산대학교
  4. 김형준교신저자서울대학교

초록

This paper proposes a base isolating system to reduce the seismic demands of low- or medium-rise structures and experimentally investigates its seismic response using shake-table tests. The base isolating system considered in this study consists of laminated-rubber bearings and U-shaped hysteretic (UH) dampers which are made of high toughness steel (HTS) and are machined with slotted holes to increase their deformation capacities. A base isolated 2-story specimen for shake-table tests was first designed and cyclic tests of laminated-rubber bearings and UH dampers implemented in the base isolating systems were then carried out. The component test for the laminated-rubber bearings shows typically low lateral stiffness with enough vertical stiffness to carry gravity loads. The test results for the UH dampers demonstrate that the use of HTS material and the introduction of the slotted holes details increase deformation capacities by inducing uniform stress distribution along a UH damper. Finally, shake-table tests were performed using specimens shaken with increasing ground acceleration records. The shake-table tests show that the proposed base isolating system with UH dampers limits the seismic demands of a base isolated structure by lengthening its structural period, concentrating displacement demands on the base isolating floor and adding seismic energy dissipation from the UH dampers.

키워드

U-shaped hysteretic damperdeformation capacitybase isolationslotted holesshake-table testsBEARINGS

식별자

WoS UID
000306221500011
KCI
ART001676142