Characteristics of ultrasonic nonlinearity by thermal fatigue
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING13(6) · pp.935 · 2012
- 피인용
- Web of Science 22KCI 4
- JCR IF
- JCR 2011 1.141
- ISSN
- 2234-7593
저자
초록
The deterioration conditions of nuclear power plants and chemical plants have raised deep concerns about the safety of high-risk structures. The safety of a structure can be secured by evaluations of breakages and lifespan in the early stage. Therefore, the material condition of a structure needs to be estimated. A nonlinear ultrasonic evaluation method is reportedly more sensitive on microscopic changes of a material than a linear evaluation method. Therefore, the nonlinear ultrasonic technique based on ultrasonic nonlinearity is considered a promising method of evaluation for breakages and lifespan. This study measured the changes in nonlinear parameters by using a nonlinear ultrasonic method, observed the microstructure of a heated material, and analyzed the relation between the size of the microstructure and the changes in the nonlinear parameters.
키워드
Nonlinear ultrasonicHeat treatmentNonlinear parameterMicrostructureDAMAGEALLOY