Endoscopic Transnasal Approach for the Treatment of Isolated Medial Orbital Blow-Out Fractures A Prospective Study of Preoperative and Postoperative Orbital Volume Change
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- ANNALS OF PLASTIC SURGERY68(2) · pp.161 · 2012
- 피인용
- Web of Science 9
- JCR IF
- JCR 2011 1.318
- ISSN
- 0148-7043
저자
- 김경훈제1저자Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- 송경호Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- 최수종Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- 배용찬Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- 최치원Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- Oh, HeungchanDepartment of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- 이재우Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
- 남수봉교신저자Department of Plastic and Reconstructive Surgery, School of Medicine, Pusan National University, South Korea
초록
Endoscopic transnasal reduction is a safe and effective technique for the treatment of blow-out fractures of the medial orbital wall. However, because this approach does not use rigid permanent material for reconstruction of the fractured medial orbital wall, some degree of herniation of the orbital contents may occur after the intraethmoidal packing material is removed. The purpose of this study was to evaluate the change in orbital volume in patients with medial orbital wall fractures treated through an endoscopic transnasal approach. This study was a prospective analysis that includes 20 patients who underwent endoscopic transnasal reduction of medial orbital wall fractures between April 2007 and December 2008. Computer-assisted orbital volume measurements were made using axial computed tomography. The mean (standard deviation inverted right perpendicular SD inverted left perpendicular) volume increase was 2.00 (0.92) cm(3) and the mean (SD) dimension of the fractured orbital wall was 2.76 (0.83) cm(2). After endoscopic surgery, an average (SD) volume decrease of 2.15 (0.91) cm(3) was achieved with ethmoid sinus packing. After removal of the packing materials, 1.14 (0.78) cm(3) increase of the orbital volume was observed. The dimension of the orbital wall fracture significantly correlated with the increased preoperative orbital volume (P = 0.002, r = 0.609); the preoperative increase in the orbital volume also significantly correlated with volume relapse after removal of the packing (P = 0.023, r = 0.452). These findings suggest that in broad orbital wall fractures, reconstruction of the orbital wall by rigid materials or prolongation of the packing period should be considered, because orbital volume can increase again after packing removal, and may thus lead to postoperative complications.
키워드
blow-out fractureorbital volumeendoscopic reductionWALLENOPHTHALMOSREDUCTIONFLOOR