본문 바로가기

Development of Gas Control System with PLC for PNU-RICH2

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q4
저널
JOURNAL OF THE KOREAN PHYSICAL SOCIETY59(2) · pp.1628 · 2011
피인용
Web of Science 1KCI 0
JCR IF
JCR 2010 0.478
ISSN
0374-4884

저자

  1. 손창욱제1저자Pusan National University
  2. 최경언Pusan National University
  3. 오근수Pusan National University
  4. 송지혜Pusan National University
  5. 이준규Pusan National University
  6. 유인권부산대학교

초록

We have developed a gaseous Ring Imaging CHerenkov detector prototype (PNU-RICH2) of the CBM-RICH detector at FAIR in GSI, and a Gas Control System (GCS) to provide and monitor the gas to the PNU-RICH2 at its test experiment. The PNU-RICH2 includes a spherical concave CBM mirror and 2 different types of Multi-anode PMTs from Hamamatsu especially in UV region efficiency. A test experiment is installed at 60 MeV electron beam line with gas system controlled by GCS using PVSS and Programmable Logic Controller. The first test results of PNU-RICH2 and GCS monitoring are presented and compared with simulations.

키워드

Ring imaging CHerenkov (RICH) detectorGas control systemPVSSProgrammable Logical Controller (PLC)

식별자

WoS UID
000294080700042
KCI
ART001579790