Correlation between Experimental Cyclic Fatigue Resistance and Numerical Stress Analysis for Nickel-Titanium Rotary Files
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1
- 저널
- JOURNAL OF ENDODONTICS37(8) · pp.1152 · 2011
- 피인용
- Web of Science 62
- JCR IF
- JCR 2010 3.291
- ISSN
- 0099-2399
저자
- 이민호제1저자Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
- Versluis, AntheunisDepartment of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, United States
- 김병민Division of Precision Manufacturing Systems, Pusan National University, South Korea
- 이찬주Division of Precision Manufacturing Systems, Pusan National University, South Korea
- 허복Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
- 김현철교신저자Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
초록
Introduction: The aim of this investigation was to study cyclic fatigue resistance of various nickel-titanium (NiTi) rotary files under various root canal curvatures by correlating cyclic fatigue fracture tests with finite-element analysis (FEA). Methods: Four NiTi rotary instruments with different cross-sectional geometries but comparable sizes were selected for this study: ProTaper (Dentsply Maillefer, Ballaigues, Switzerland), ProFile (Dentsply Maillefer), HeroShaper (Micromega, Besancon, France), and Mtwo (VDW, Munich, Germany). The ProFile and HeroShaper files were of size 30/.06 taper, the Mtwo was of size 30/.05 taper, and the ProTaper was F3. The cyclic fatigue test was conducted in a custom-made device that simulated canals with 25 degrees, 35 degrees, and 45 degrees curvature. For the FEA, the file models were meshed, and 17-mm long curved canals were modeled to have same curvatures as the cyclic fatigue tests. Numerical analysis was performed to determine the stress distributions in the NiTi instruments while they rotated in the simulated curved canals. Results: ProTaper (the stiffest instrument) showed the least cyclic fatigue resistance and highest stress concentration for all tested curvatures, whereas Mtwo showed the best cyclic fatigue resistance. A comparison between the FEA and fatigue results showed that when stresses increased, the number of instrument rotations to fracture decreased. Maximum stresses in the instruments predicted the approximate location of the fatigue fracture. Conclusions: The stiffer instrument had the highest stress concentration in FEA and the least number of rotations until fracture in the cyclic fatigue test. Increased curvature of the root canal generated higher stresses and shortened the lifetime of NiTi files. Finite-element stress analysis reflected cyclic fatigue fracture resistance. (J Endod 2011;37:1152-1157)
키워드
Cyclic fatiguefinite-element analysisfracture susceptibilitynickel-titanium fileroot canal curvatureSIMULATED CURVED CANALSFINITE-ELEMENT-ANALYSISCLINICAL-USESTAINLESS-STEELPROTAPER-S1 INSTRUMENTSBENDING PROPERTIESCROSS-SECTIONSROOT CANALSFRACTUREDEFECTS
식별자
- WoS UID
- 000294091500022



로그인
연구물 목록으로