Diode-pumped solid-state laser for bonding orthodontic brackets: effect of light intensity and light-curing time
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1
- 저널
- LASERS IN MEDICAL SCIENCE26(5) · pp.585 · 2011
- 피인용
- Web of Science 3
- JCR IF
- JCR 2010 2.311
- ISSN
- 0268-8921
저자
- 김영오제1저자Department of Orthodontics, School of Dentistry, Pusan National University, South Korea
- 박수병Department of Orthodontics, School of Dentistry, Pusan National University, South Korea
- 손우성Department of Orthodontics, School of Dentistry, Pusan National University, South Korea
- Ko, Ching-ChangDepartment of Orthodontics, School of Dentistry, University of North Carolina, United States
- García-Godoy, FranklinCollege of Dentistry, University of Tennessee, United States
- 김형일Department of Orthodontics, School of Dentistry, Pusan National University, South Korea
- 권용훈교신저자Department of Dental Materials, School of Dentistry, Pusan National University, South Korea
초록
This study evaluated the shear bond strength (SBS) of orthodontic brackets bonded to teeth using a diode-pumped solid state (DPSS) laser of 473 nm with various light intensity and light-curing settings. For the study, a total of 150 extracted human teeth were divided into ten groups. In the control group, the brackets were bonded to the teeth using a quartz-tungsten-halogen (QTH) light with an intensity of 900 mW/cm(2). In the experimental groups, the brackets were bonded using a DPSS laser with three different light intensities and light-curing times. The same bracket type and adhesive were used in all groups throughout the study. Statistical analysis was performed to compare the SBS, and adhesive remnant index (ARI) among the groups. As results, brackets bonded using the DPSS laser with an intensity of 700 mW/cm(2) for 40 s (totally) showed a slightly higher SBS (12.2 +/- 1.8 MPa) than that of those bonded using a QTH light (control; 11.6 +/- 1.6 MPa). The SBS values linearly increased with increasing energy density (light intensity x light-curing time) of the DPSS laser (R = 0.95, p < 0.001). However, the SBS values among the test groups were similar regardless of the difference in light-curing conditions. A comparison of the ARI scores among the groups suggested a similar bracket failure mode.
키워드
DPSS laserOrthodontic bracketShear bond strengthQTH lightTEMPERATURE RISERESIN COMPOSITESARGON-LASERPLASMA-ARCQTHPOLYMERIZATIONMICROHARDNESSUNITSRESTORATIONSSTRENGTH
식별자
- WoS UID
- 000293650000005



로그인
연구물 목록으로