Influence of DPSS Laser on Polymerization Shrinkage and Mass Change of Resin Composites
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2
- 저널
- PHOTOMEDICINE AND LASER SURGERY29(8) · pp.545 · 2011
- 피인용
- Web of Science 3
- JCR IF
- JCR 2010 1.633
- ISSN
- 1549-5418
저자
- 신동희제1저자Department of Dental Materials, College of Dentistry and Pusan National University Hospital Medical Research Institute, Pusan National University, South Korea
- 윤동인Department of Dental Materials, College of Dentistry and Pusan National University Hospital Medical Research Institute, Pusan National University, South Korea
- Park, Mi-GyongDepartment of Dental Laboratory Science, Catholic University of Pusan, South Korea
- Ko, Ching-ChangDepartment of Orthodontics, School of Dentistry, University of North Carolina, United States
- García-Godoy, FranklinCollege of Dentistry, University of Tennessee, United States
- 김형일Department of Dental Materials, College of Dentistry and Pusan National University Hospital Medical Research Institute, Pusan National University, South Korea
- 권용훈교신저자Department of Dental Materials, College of Dentistry and Pusan National University Hospital Medical Research Institute, Pusan National University, South Korea
초록
Objectives: This study evaluated the effectiveness of the diode-pumped solid state (DPSS) laser as a light source for light-curing dental resin composites. Background data: A DPSS laser of 473 nm may be useful because of its match with the absorption peak of camphorquinone (CQ), the photoinitiator. Materials and methods: A DPSS laser (LAS) of 473 nm and a quartz-tungsten-halogen (QTH) light-curing unit (OP) were used as the light sources for light curing six different resin composites (four nanocomposites and two hybrid composites). Polymerization shrinkage and mass change (water sorption and solubility) were measured during and after light curing to determine the degree of polymerization. Mass change was evaluated by following the ISO 4049 standard. Results: According to the evaluation, the specimens light cured using LAS showed similar maximum polymerization shrinkage (12.3 similar to 18.1 mu m for LAS; 13.2 similar to 16.2 mu m for OP) and water sorption (11.4 similar to 24.1 mu g/mm(3) for LAS; 11.3 similar to 22.8 mu g/mm(3) for OP) to the cases light cured using OP. The specimens light cured using LAS showed a significantly higher solubility than the cases light cured using OP (2.4 similar to 6.6 mu g/mm(3) for LAS; 0.8 similar to 1.6 mu g/mm(3) for OP). However, the maximum water sorption and solubility obtained from the specimens were lower than the values permitted by the ISO 4049 standard. Conclusions: The results may suggest that the DPSS laser with an emission wavelength of 473 nm can be used as a light source for light-curing dental resin composites.
키워드
ARGON ION LASERWATER SORPTIONDENTAL COMPOSITESMECHANICAL-PROPERTIESTEMPERATURE RISEFLOW-CYTOMETRYWET CONDITIONSHALOGEN LIGHTCURING LIGHTSMICROHARDNESS