A photo-multiplier tube-based hybrid MRI and frequency domain fluorescence tomography system for small animal imaging
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1
- 저널
- PHYSICS IN MEDICINE AND BIOLOGY56(15) · pp.4731 · 2011
- 피인용
- Web of Science 32
- JCR IF
- JCR 2010 3.057
- ISSN
- 0031-9155
저자
- Lin, Y.제1저자교신저자Tu and Yuen Center for Functional Onco Imaging, University of California, United States
- Ghijsen, M. T.Tu and Yuen Center for Functional Onco Imaging, University of California, United States
- Gao, H.Department of Mathematics, University of California, United States
- Liu, N.Tu and Yuen Center for Functional Onco Imaging, University of California, United States
- 오르한 날시오그루Department of Cogno-Mechatronics Engineering, Pusan National University, South Korea
- Gulsen, G.Tu and Yuen Center for Functional Onco Imaging, University of California, United States
초록
Fluorescence tomography (FT) is a promising molecular imaging technique that can spatially resolve both fluorophore concentration and lifetime parameters. However, recovered fluorophore parameters highly depend on the size and depth of the object due to the ill-posedness of the FT inverse problem. Structural a priori information from another high spatial resolution imaging modality has been demonstrated to significantly improve FT reconstruction accuracy. In this study, we have constructed a combined magnetic resonance imaging (MRI) and FT system for small animal imaging. A photo-multiplier tube is used as the detector to acquire frequency domain FT measurements. This is the first MR-compatible time-resolved FT system that can reconstruct both fluorescence concentration and lifetime maps simultaneously. The performance of the hybrid system is evaluated with phantom studies. Two different fluorophores, indocyanine green and 3-3' diethylthiatricarbocyanine iodide, which have similar excitation and emission spectra but different lifetimes, are utilized. The fluorescence concentration and lifetime maps are both reconstructed with and without the structural a priori information obtained from MRI for comparison. We show that the hybrid system can accurately recover both fluorescence intensity and lifetime within 10% error for two 4.2 mm-diameter cylindrical objects embedded in a 38 mm-diameter cylindrical phantom when MRI structural a priori information is utilized.
키워드
DIFFUSE OPTICAL TOMOGRAPHYA-PRIORI INFORMATIONMOLECULAR TOMOGRAPHYLIFETIME TOMOGRAPHYFEASIBILITYPHANTOMTISSUEMODELPROBE
식별자
- WoS UID
- 000292885000008



로그인
연구물 목록으로