Ultrasensitive immunosensing of tuberculosis CFP-10 based on SPR spectroscopy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1
- 저널
- SENSORS AND ACTUATORS B-CHEMICAL156(1) · pp.271 · 2011
- 피인용
- Web of Science 44
- JCR IF
- JCR 2010 3.37
- ISSN
- 0925-4005
저자
- 홍성철제1저자Department of Nanomedical Engineering, Pusan National University, South Korea
- Chen, HongxiaSchool of Life Sciences, Shanghai University, China
- 이재욱Department of Nanomedical Engineering, Pusan National University, South Korea
- 박혜경School of Medicine, Pusan National University, South Korea
- Kim, Young SikDepartment of Chemistry Education, Korea National University of Education, South Korea
- Shin, Hyun-ChulDepartment of Chemistry Education, Korea National University of Education, South Korea
- 김철민School of Medicine, Pusan National University, South Korea
- Park, Tae JungBioprocess Engineering Research Center, Center for Systems and Synthetic Biotechnology, Institute for the BioCentury, South Korea
- Lee, Seok JaeNEMS-Bio Team, National NanoFab Center, South Korea
- 고광락Department of Nanomedical Engineering, Pusan National University, South Korea
- Kim, Hwa-JungDepartment of Microbiology, Research Institute for Medical Science, Chungnam National University, South Korea
- 장철훈교신저자School of Medicine, Pusan National University, South Korea
- 이재범Department of Nanomedical Engineering, Pusan National University, South Korea
초록
An antigen (Ag), CFP-10, found in tissue fluids of tuberculosis (TB) patients may be an ultimate candidate for use as a sensitive TB marker with a sensing method for early simplified diagnosis of TB. In this study, chemical and optical optimizations were carried out using novel immuno-materials for establishment of a self-assembled surface plasmon resonance (SPR) optical immunosensor system for detection of CFP-10, which is valuable for pre-clinical work, prior to conduct of massive clinical observations. For creation of a simple sensing interface, a monoclonal antibody (anti-CFP-10) was immobilized directly on a gold surface, followed by blocking with cystamine. Orientation and accessibility of anti-CFP-10 were assessed by the selective binding of CFP-10. Recent results indicate that the reusability of the sensor chip adopting the cystamine method was found to be preferable to other immobilization methods. A linear relationship was well correlated between SPR angle shift and CFP concentrations in the range from 100 ng mL(-1) to 1 mu g mL(-1). Modification of the SPR chip with antibody provides a simple experimental platform for investigation of isolated proteins under experimental conditions resembling those of their native environment. (C) 2011 Elsevier B.V. All rights reserved.
키워드
Tuberculosis (TB)CFP-10Surface plasmon resonance (SPR)spectroscopyBiosensorSELF-ASSEMBLED MONOLAYERSMYCOBACTERIUM-TUBERCULOSISINFECTIONIMMUNOASSAYDIAGNOSISPROTEINASSAYGOLD
식별자
- WoS UID
- 000292058200039



로그인
연구물 목록으로