Cryogenic Fatigue Strength Assessment for MARK-III Insulation System of LNG Carriers

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4
피인용
Web of Science 7
JCR IF
JCR 2010 0.277
ISSN
0892-7219

저자

  1. 김명현제1저자부산대학교, 공과대학, 조선·해양공학과, KO
  2. 길윤표부산대학교, 공과대학, KO
  3. 이제명부산대학교, 공과대학, 조선·해양공학과, KO
  4. Chun, Min Sung교신저자삼성, Geoje 656710, KO
  5. Suh, Yong Suk삼성, Geoje 656710, KO
  6. Kim, Wha Soo현대, KO
  7. Noh, Byung Jae현대, KO
  8. Yoon, Jang HoAmerican Bureau of Shipping, KO
  9. Kim, Min SooLloyds Register, KO
  10. Urm, Hang SubDet Norske Veritas Korea Ltd, KO

초록

The objective of this study is to investigate the typical failure mode and to obtain the stress range versus number of cycles to failure (S-N) data of MARK-III type liquefied natural gas (LNG) insulation system under the fatigue loading at actual cryogenic environment. A systematic experimental research is carried out for the assessment of the fatigue strength of MARK-III insulation system at cryogenic temperature. Three different types of test specimens are tested for the evaluation of fatigue performance of MARK-III insulation system. Test specimens are determined considering the fatigue vulnerable locations such as mastic area, slit area, and top bridge pad area inside the actual LNG cargo tanks. All test specimens are fabricated as close as possible to the actual yard practice. A series of fatigue test results is represented as S-N curves. Cyclic fatigue loadings were carefully considered similar to the actual sloshing loads. The effect of sloshing impacts is considered by selecting the stress ratio (R = -10). The load levels have been determined based on the ultimate strength of reinforced polyurethane foam as 12.2 bars. Different cryogenic temperatures are employed according to the test locations in consideration of temperature gradient within the insulation system. All test results including fatigue life, as well as failure locations of MARK-III insulation system at cryogenic temperatures, are reported and compared with those at room temperature. Consistent S-N curves of MARK-III insulation system at both room and cryogenic temperatures are obtained and compared. The slopes of S-N curves from both fatigue test results are observed to be almost identical, and the fatigue strengths are found to exhibit similar trend. The results from this research can be used for the fatigue assessment of the LNGC insulation system, as well as a design guideline of LNG CCS at cryogenic temperature. [DOI:10.1115/1.4003389]

키워드

cryogenic fatiguefatigue strengthMark-III membrane systemLNG carriersinsulation systemS-N curves

식별자

WoS UID
000289431200008