본문 바로가기

Performance Evaluation of Real-Q Enterovirus Quantification Kit for Enterovirus by Real-time PCR

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널
Korean Journal of Laboratory Medicine30(6) · pp.624 · 2010
피인용
Web of Science 0
JCR IF
JCR 2009 0.626
ISSN
1598-6535

저자

  1. 송두열제1저자Department of Laboratory Medicine, Pusan National University, School of Medicine, South Korea
  2. 김신영Department of Laboratory Medicine, Pusan National University, School of Medicine, South Korea
  3. 조선아Department of Laboratory Medicine, Pusan National University, School of Medicine, South Korea
  4. 함형일Department of Medicine, Pusan National University, School of Medicine, South Korea
  5. 황상현교신저자Medical Research Institute, Pusan National University Hospital, South Korea
  6. 임영탁Department of Pediatrics, Pusan National University, School of Medicine, South Korea
  7. 김형회Department of Laboratory Medicine, Pusan National University, School of Medicine, South Korea
  8. 장철훈Department of Laboratory Medicine, Pusan National University, School of Medicine, South Korea
  9. 이은엽Department of Laboratory Medicine, Pusan National University, School of Medicine, South Korea

초록

Background : Molecular methods have enabled rapid diagnosis of aseptic meningitis and have reduced both unnecessary therapeutic interventions and medical costs. In this study, we evaluated the analytical performance of the recently developed Real-Q Enterovirus Quantification kit (BioSe-woom Inc., Korea). Methods : We evaluated the detection limit, precision, linearity, and cross-reactivity of the Real-Q Enterovirus Quantification kit and compared it with the conventional PCR method. From March to September 2009, we tested 91 CSF specimens from patients who visited the pediatrics department of the university hospital with symptoms of aseptic meningitis or infantile sepsis, and we also tested 48 CSF specimens from patients with febrile convulsion for differential diagnosis. Results : The Real-Q Enterovirus Quantification kit showed good linearity (r=0.997) within a range from 3 x 10(2) to 3 x 10(10) copies/mL, and the detection limit of the kit was 83 copies/mL. The within-run, between-run, and between-day CVs were 5.3-7.6%, 9.5-12.3%, and 11.4-13.4%, respectively. There was no cross reactivity between enteroviruses and various microorganisms. Positive results were obtained for 39.1% (25/64) of the patients suspected of aseptic meningitis and 44,4% (12/27) of the patients suspected of infantile sepsis. However, among the 48 children with febrile conversion, only 4 were positive for enterovirus. Further, the concordance with conventional FOR was high (73/74). Conclusions : The Real-Q Enterovirus Quantification kit showed excellent linearity and high reliability with a broad reportable range. It showed good detection rate when used with clinical specimens and also showed a high concordance with the conventional method. Therefore, this assay would be clinically useful not only in diagnosis of aseptic meningitis but also in differential diagnosis of infantile sepsis. (Korean J Lab Med 2010;30:624-30)

키워드

Human enterovirusesAseptic meningitisReal time PCRPerformance evaluationCerebrospinal fluidPOLYMERASE-CHAIN-REACTIONCEREBROSPINAL-FLUID SPECIMENSCLINICAL SPECIMENSRAPID DETECTIONDIAGNOSISASSAYIDENTIFICATIONAMPLIFICATIONMANAGEMENTINFANTS

식별자

WoS UID
000285530300016