Outcomes Following Use of a Modified Duran Ring Tricuspid Valve Reconstruction Procedure for Secondary Tricuspid Regurgitation
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2
- 저널
- CIRCULATION JOURNAL74(5) · pp.925 · 2010
- 피인용
- Web of Science 13
- JCR IF
- JCR 2009 2.692
- ISSN
- 1346-9843
저자
- Jung, Sung-Ho제1저자Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, South Korea
- 제형곤Department of Cardiovascular Surgery, Pusan National University Yangsan Hospital, South Korea
- Song, Jong MinDepartment of Cardiology, Asan Medical Center, College of Medicine, University of Ulsan, South Korea
- Choo, Suk JungDepartment of Thoracic and Cardiovascular Surgery, Asan Medical Center, South Korea
- Chung, Cheol HyunDepartment of Thoracic and Cardiovascular Surgery, Asan Medical Center, South Korea
- Yun, Sung CheolDepartment of Preventive Medicine, Asan Medical Center, College of Medicine, University of Ulsan, South Korea
- Lee, Jae Won교신저자Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, South Korea
초록
Background: Tricuspid valve (TV) repair using ring annuloplasty is reportedly to be superior to suture annuloplasty for treating tricuspid regurgitation (TA). The Duran ring TV annuloplasty technique was modified in order to reduce the risk of complete atrioventricular block and aortic valve injury and the outcomes are reported here. The modification involved not suturing half of the septal annulus. Methods and Results: Between January 1998 and July 2007, 219 patients diagnosed with secondary TA underwent TV repair using a modified Duran ring procedure. The mean patient age was 54.2 +/- 12.7 years, and 65 (29.7%) patients were male. The median follow-up duration was 35.8 months (range, 0.03-122.6 months). The mean ring size was 27.4 +/- 2.0 mm. The prevalence of 3+ or 4+ regurgitation was 9.5% (21/218) at 1 week postoperatively, and 9.4% at more than 2 years postoperatively (mean, 57 months; 96 patients assessed). The in-hospital mortality rate was 1.4% (3/219). The overall survival rate was 95 +/- 1.5% at 1 year, 86.2 +/- 3.0% at 5 years, and 79.9 +/- 4.2% at 8 years. Multivariate analysis showed that atrial fibrillation at the last follow-up (P<0.001) and cardiopulmonary bypass time (P=0.016) were risk factors for recurrent or persistent significant TR. Conclusions: The modified Duran ring TV repair procedure for secondary TA patients was safe and durable. Notably, postoperative atrial fibrillation was found to be a significant risk factor for recurrent TR. (Circ J 2010; 74: 925-930)
식별자
- WoS UID
- 000277226100020



로그인
연구물 목록으로