본문 바로가기

Development and implementation of a corrosion control algorithm based on calcium carbonate precipitation potential (CCPP) in a drinking water distribution system

문서 유형
연구출판물 · 학술지 논문
등재
SCIE
저널
Aqua57(7) · pp.531 · 2008
피인용
Web of Science 7
ISSN
0003-7214

저자

  1. 김도환제1저자Department of Environmental Engineering, Pusan National University, South Korea
  2. 김동연Department of Environmental Engineering, Pusan National University, South Korea
  3. 홍순헌Department of Industrial Civil, Pusan National University, Miryang Campus, South Korea
  4. 김지원Department of Environmental Engineering, Pusan National University, South Korea
  5. 김창원교신저자Department of Environmental Engineering, Pusan National University, South Korea

초록

Water corrosiveness depends mainly on the chemical factors of pH, alkalinity, Ca2+ concentration, dissolved oxygen, and total dissolved solids (TDS), and on the physical factors of temperature and flow velocity as well as pipe materials. The calcium carbonate precipitation potential (CCPP) control process and a simulated water distribution system (SWDS) were installed for a pilot-scale advanced water treatment process. The system was operated for 2 years. The CCPP control algorithm for anti-corrosion of a pipeline was developed and validated. The target CCPP value could be controlled by manipulating the pH and alkalinity with additions of sodium carbonate (Na2CO3) and carbon dioxide (CO2) where enough calcium was present. The CCPP range of 0 similar to 4 mgL(-1) was controlled reasonably to induce a calcium carbonate (CaCO3) film on the surface of the pipeline, which provided the anti-corrosion effect. The proper range required of pH and alkalinity used to manipulate the range of 0 similar to 4 mgL(-1) of CCPP was 8.0 similar to 8.3, 70 similar to 100 mgL(-1) as CaCO3 when the Ca2+ concentration was in the range of 60 similar to 80 mgL(-1) as CaCO3, respectively, in this research. The effect of corrosion control was demonstrated by reduced iron and zinc concentrations released from the pipe material. This result might indicate the presence of the CaCO3 film and the efficacy of its anti-corrosion effect. However, the simple proportional integral derivative (PID) controller's sensitivity seemed to be in need of further improvement.

키워드

CaCO3CCPPcorrosion controlcorrosivenesswater distribution systemMODEL

식별자

WoS UID
000259701600007