본문 바로가기

Clinical safety of drug-eluting Stents in the Korea acute myocardial infarction registry

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2
저널
CIRCULATION JOURNAL72(3) · pp.392 · 2008
피인용
Web of Science 37
JCR IF
JCR 2007 2.373
ISSN
1346-9843

저자

  1. Sang, Rok Lee제1저자Chonbuk National University, Research Institute of Medical Science, South Korea
  2. Myung, Ho Jeong교신저자Chonnam National University, Research Institute of Medical Science, South Korea
  3. Young, Keun AhnChonnam National University, Research Institute of Medical Science, South Korea
  4. Shung, Chull ChaeKyungpook National University, South Korea
  5. Seung, Ho HurKeimyung University, South Korea
  6. Young, Jo KimYeungnam University, South Korea
  7. In, Whan SeongChungnam National University, South Korea
  8. Jei, Keon ChaeChonbuk National University, Research Institute of Medical Science, South Korea
  9. 홍택종Pusan National University, South Korea
  10. Jae, Young RhewJeonju Presbyterian Medical Center, South Korea
  11. Myeong, Chan ChoChungbuk National University, South Korea
  12. Jang, Ho BaeKonyang University, South Korea
  13. Seung, Woon RhaKorea University, South Korea
  14. Chong, Jin KimKyunghee University, South Korea
  15. Yang, Soo JangYonsei University, South Korea
  16. Seung, Jung ParkAsan Medical Center, University of Ulsan, South Korea
  17. Jong, Hyun Kim
  18. Dong, Hoon Choi
  19. Doo, Il Kim
  20. In, Ho Chae
  21. Jung, Han Yoon
  22. Bon, Kwon Koo
  23. Byung, Ok Kim
  24. Myoung, Yong Lee
  25. Kee, Sik Kim
  26. Jin, Yong Hwang
  27. Seok, Kyu Oh
  28. Nae, Hee Lee
  29. Kyoung, Tae Jeong
  30. Seung, Jea Tahk
저자 46명 모두 보기

초록

Background Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) may be useful in patients with acute myocardial infarction (AMI), but safety issues still need to be solved. This study was undertaken to investigate the incidence of major adverse cardiac events (MACE) and stent thrombosis in DES-implanted AMI patients in real-life clinical practice. Methods and Results On-line registry of AMI cases at the web site www.kamir.or.kr has been performed in 41 primary PCI centers in Korea and between November 2005 and September 2006, 1,541 surviving patients who had been implanted with either Cypher (R) or Taxus (R) stents were enrolled for analysis during a 6-month clinical follow-up. There were 2 groups: group 1 [834 patients, 61.9 +/- 11.9 years: sirolimus-eluting stent (Cypher (R) )], group II [707 patients, 62.9 +/- 12.0 years: paclitaxel-eluting stent (Taxus (R))]. At both 1 and 6 months the incidence of MACE was not significantly different between the 2 groups. There were 17 cases of stent thrombosis, but the incidence of stent thrombosis was not significantly different between the 2 groups (group I:II=9 (1.1%):8 (1.1%), p=1.000). The stent type, length, number, lesion complexity and diabetes were not significant for the incidence of MACE or stent thrombosis after adjustment. Conclusion MACE and stent thrombosis rates did not differ between 2 types of DES identified in Korea Acute Myocardial Infarction Registry (KAMIR). DES can be used in patients with AMI with a relatively low 6-month MACE rate.

식별자

WoS UID
000253521500008