Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1
- 저널
- INTERNATIONAL ENDODONTIC JOURNAL42(1) · pp.14 · 2009
- 피인용
- Web of Science 77
- JCR IF
- JCR 2008 2.465
- ISSN
- 0143-2885
저자
- Kim, T. O.제1저자교신저자Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
- Cheung, G. S.P.Area of Endodontics, Faculty of Dentistry, University of Hong Kong, Hong Kong
- 이정민Division of Precision Manufacturing Systems, Pusan National University, South Korea
- 김병민Division of Precision Manufacturing Systems, Pusan National University, South Korea
- 허복Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
- 김현철Department of Conservative Dentistry, School of Dentistry, Pusan National University, South Korea
초록
To compare and evaluate the stress distribution of three NiTi instruments of various cross-sectional configurations under bending or torsional condition using a finite-element analysis model. Three NiTi files (ProFile, ProTaper and ProTaper Universal) were scanned using Micro-CT to produce a three-dimensional digital model. The behaviour of the instrument under bending or torsional loads was analysed mathematically in software (ABAQUS V6.5-1), taking into consideration the nonlinear mechanical characteristic of NiTi material. ProFile showed the greatest flexibility, followed by ProTaper Universal and ProTaper. The highest stress was observed at the surface near the cutting edge and the base of (opposing) flutes during cantilever bending. Concentration of stresses was observed at the bottom of the flutes in ProFile and ProTaper Universal instruments in torsion. The stress was more evenly distributed over the surface of ProTaper initially, which then concentrated at the middle of the convex sides when the amount of angular deflection was increased. Incorporating a U-shaped groove in the middle of each side of the convex-triangular design lowers the flexural rigidity of the origin ProTaper design. Bending leads to the highest surface stress at or near the cutting edge of the instrument. Stress concentration occurs at the bottom of the flute when the instrument is subjected to torsion.