본문 바로가기

A basic study on the dynamic water level limit sensor utilizing acoustic impedance matching

문서 유형
연구출판물 · 학술대회 발표논문
등재
SCIEScopus
저널
JOURNAL OF ELECTROCERAMICS17(2-4) · pp.531 · 2006
피인용
Web of Science 0
ISSN
1385-3449

저자

  1. 김철한제1저자Department of Electronic Engineering, Busan National University, South Korea
  2. Lee, Su-HoDepartment of Electrical Engineering, Dong-A University, South Korea
  3. Sa-Gong, Geon교신저자Department of Electrical Engineering, Dong-A University, South Korea
  4. Lee, Jun-HeeDivision of Metallurgical Materials and Chemical Engineering, Dong-A University, South Korea

초록

In this study, an ultrasonic level limit sensor with a new structure utilizing the acoustic impedance matching is proposed in order to check the change of water-level. Two PZT resonators with the same property are bonded directly on a polyethylene plate. The first one is for transmitter as an ultrasonic transducer and the other is for a receiver. In this case, a polyethylene plate will operate as an acoustic guider to propagate a transverse wave between the two PZT resonators in air. On the other hand, a polyethylene plate having similar acoustic impedance with the water will be emitting an acoustic energy into the water as a longitudinal wave in the water. According to this mechanism, there was large difference of acoustic output signal between underwater and air. Therefore, it is believed that this proposed level limit sensor could be used as a new dynamic one, toughened from the external mechanical noise.

식별자

WoS UID
000243610600076