A study on ultrasonic testing for nondestructive evaluation of thermal fatigue crack in pipelines
- 문서 유형
- 연구출판물 · 학술대회 발표논문
- 등재
- SCIEScopus
- 저널
- KEY ENGINEERING MATERIALS321-323 · pp.747 · 2006
- 피인용
- Web of Science 4
- ISSN
- 1013-9826
저자
- Yi, Won-Geun제1저자부산대학교, 공과대학, 기계공학부, KO
- Lee, Min-Rae부산대학교, 공과대학, 기계공학부, KO
- 이준현부산대학교, 공과대학, 기계공학부, KO
- Choi, Sang-Woo부산대학교, 공과대학, 기계공학부, KO
- Lee, Bo-Young한국항공대학교, 기계공학부, KO
초록
Pipelines of nuclear power plants undergo high pressure and temperature. Thermal stratification typically occurs in the surge line and the main feed water lines by flow and this stratification will initiate and propagate thermal fatigue cracks. This may cause rupture and leakage and it is a serious problem to nuclear power plants operation. Therefore it is very important to detect and measure thermal fatigue cracks. In this study, thermal fatigue cracks were generated in austenitic stainless steel specimens by a thermal cycle in notched pipes and weld jointed pipes. Ultrasonic techniques were used to evaluate the thermal fatigue crack depth. When ultrasonic waves propagate from an angle beam probe to thermal fatigue cracks, waves are reflected and diffracted. Crack depth was evaluated by the reflected signals from back wall and diffracted signals from the crack tip, but diffracted signals were too weak to detect so the reflected signals were more useful. The TOFD and dB drop methods were used in this study. The TOFD method is uses a time delay of diffracted signal from the crack tip. The dB drop method is an application of an amplitude decreasing rate by a probe moving distance.
식별자
- WoS UID
- 000241427900167



로그인
연구물 목록으로