Heparin Wet Suction Versus Conventional Suction in Endoscopic Ultrasound-Guided Fine-Needle Biopsy for Solid Pancreatic Masses: A Multicenter Randomized Crossover Study
- Document Type
- Publications · Journal Article
- Registered DB
- SCIEScopus
- Journal Ranking
- JCR Q2Scopus Q1
- Journal
- JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY2026
- Citation
- Web of Science 0Scopus 0
- JCR IF
- JCR 2024 3.4
- ISSN
- 0815-9319
Authors
- Chon, Hyung KuFirst authorWonkwang Univ, Inst Wonkwang Med Sci, Coll Med, Div Biliopancreas,Dept Internal Med, Iksan, South Korea
- Jang, Dong KeeSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Med, Seoul, South Korea
- Paik, Woo HyunSeoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Internal Med, Seoul, South Korea
- Kim, Seong-HunJeonbuk Natl Univ, Jeonbuk Natl Univ Hosp, Biomed Res Inst, Dept Internal Med,Res Inst Clin Med, Jeonju, South Korea
- Oh, DongwookUniv Ulsan, Coll Med, Asan Med Ctr, Dept Gastroenterol, Seoul, South Korea
- Cho, EunaeChonnam Natl Univ, Med Sch & Hosp, Dept Internal Med, Gwangju, South Korea
- Park, Se WooHallym Univ, Coll Med, Dongtan Sacred Heart Hosp, Dept Internal Med,Div Gastroenterol, Hwaseong Si, South Korea
- Choe, Jung WanKorea Univ, Ansan Hosp, Coll Med, Div Gastroenterol,Dept Internal Med, Ansan, South Korea
- Kim, Eui JooGachon Univ, Gil Med Ctr, Coll Med, Div Gastroenterol,Dept Internal Med, Incheon, South Korea
- Han, Sung YongPusan Natl Univ, Pusan Natl Univ Hosp, Internal Med & Biomed Res Inst, Div Gastroenterol & Hepatol, Busan, South Korea
- Cho, Jae HeeCorresponding authorYonsei Univ, Gangnam Severance Hosp, Coll Med, Div Gastroenterol,Dept Internal Med, Seoul, South Korea
- Lee, Sang HyubCorresponding authorSeoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Dept Internal Med, Seoul, South Korea
Abstract
Background and Aim The heparin wet suction technique (HWST) may improve tissue quality in endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) by preventing blood clot formation within the needle. We compared the diagnostic performance and safety of HWST with the conventional suction technique (CST), using a novel 22-gauge FNB needle in patients with solid pancreatic masses.Methods In this multicenter, single-blinded, randomized crossover trial, patients with solid pancreatic masses (>= 1 cm) were randomized 1:1 to HWST-first or CST-first. Each patient underwent one pass with each technique using the novel 22-gauge needle. The primary outcome was diagnostic yield; secondary outcomes included technical success, adverse events, and adequacy for immunohistochemistry (IHC).Results Of 174 randomized patients, 170 received both interventions and were analyzed; baseline characteristics were comparable. The diagnostic yield was 82.9% (95% confidence interval [CI], 76.6-87.9) with HWST and 83.5% (95% CI, 77.2-88.4) with CST. The paired difference was -0.6 percentage points (95% CI, -6.7 to 5.5; exact McNemar p = 1.000). The combined diagnostic yield after sequential sampling was 91.2% (95% CI, 86.0-94.6). Technical success was 100% with both techniques, and IHC adequacy was similar (HWST: 80.6% vs. CST: 78.8%). One self-limiting bleeding event occurred during CST.Conclusions HWST showed diagnostic yield, technical success, and safety comparable to CST. Both techniques are highly effective for EUS-FNB of solid pancreatic masses. Sequential sampling may improve overall diagnostic yield, although this finding should be interpreted cautiously and requires further validation.
Keywords
biopsydiagnosisendosonographypancreatic neoplasmsTISSUE ACQUISITIONSLOW-PULLEUS-FNAASPIRATIONLESIONS
Identifiers
- Scopus EID
- 2-s2.0-105051189396
- WoS UID
- 001878899700001



Login
Back to Publication list