Skip to content

Experimental Validation of a Small-Scale Metafoundation Using Shaking Table Tests

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q2Scopus Q1
Journal
APPLIED SCIENCES-BASEL16(13) · #6513 · 2026
Citation
Web of Science 0Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 2.5
ISSN
2076-3417

Authors

  1. Lee, Jin HoFirst authorPukyong Natl Univ, Dept Ocean Engn, Busan 48513, South Korea
  2. Nguyen, An Mau NhatPukyong Natl Univ, Dept Ocean Engn, Busan 48513, South Korea
  3. Cho, Jeong-RaeCorresponding authorKorea Inst Civil Engn & Bldg Technol, Dept Struct Engn Res, Goyang 10223, South Korea
  4. Lee, SanghoKorea Inst Civil Engn & Bldg Technol, Dept Struct Engn Res, Goyang 10223, South Korea
  5. Yoon, HyejinKorea Inst Civil Engn & Bldg Technol, Dept Struct Engn Res, Goyang 10223, South Korea
  6. Park, Dong-UkPusan Natl Univ, Seism Res & Test Ctr, Yangsan 50612, South Korea
  7. Jeon, Bub-GyuPusan Natl Univ, Seism Res & Test Ctr, Yangsan 50612, South Korea

Abstract

Buried mass-resonator systems, including metafoundations, have attracted increasing attention as an effective approach for mitigating vibrations induced by seismic waves in structural systems. In this study, a series of shaking table tests are conducted on a small-scale metafoundation to experimentally evaluate its vibration reduction performance under seismic excitation. The metafoundation model was fabricated using acrylic plastic and ethylene propylene diene monomer (EPDM) rubber foam, and its dynamic characteristics were examined through white noise and sine sweep tests. The attenuation zones identified from the experiments were validated through comparison with the frequency band gaps (FBGs) of the metamaterial obtained from numerical simulations. A simple small-scale structure was subsequently installed on the metafoundation, and the dynamic behavior of the combined system was investigated using white noise and sine sweep signals. The effectiveness of the metafoundation in reducing the seismic response of the structural system was further evaluated using earthquake ground motions. The experimental results demonstrate that the metafoundation significantly reduces the seismic response of the structural system at frequencies corresponding to the attenuation zone of the structural system with metamaterial.

Keywords

metamaterialmetafoundationburied mass-resonatorshaking table testvibration isolationseismic wave

Identifiers

Scopus EID
2-s2.0-105044513334
WoS UID
001818092800001