Skip to content

Preterm Optic Disc Morphology on Handheld OCT and 5-Year Visual Outcomes

Document Type
Publications · Journal Article
Registered DB
ESCIScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
OPHTHALMOLOGY SCIENCE6(7) · 2026
Citation
Scopus 0
FWCI (Scopus)
0
JCR IF
JCR 2024 4.6
ISSN
2666-9145

Authors

  1. Guillen, RodrigoFirst authorUniversity of Washington School of Medicine, Seattle, WA, USA.
  2. Alomar, Zahraa OmarUniversity of Washington School of Medicine, Seattle, WA, USA.
  3. Jeon, Hye ShinPusan National University, Busan, South Korea.
  4. Ding, LeonaDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
  5. Park, ClaireDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
  6. Bunk, JasonDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
  7. Grant, LauraMillman-Derr, Rochester Hills, MI, USA.
  8. Shariff, AyeshaBaylor Scott and White Clinic, Georgetown, TX, USA.
  9. Gillette, Thomas B.Southwest Eyecare, Albuquerque, NM, USA.
  10. Legocki, AlexDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
  11. Tarczy-Hornoch, KristinaDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.
  12. Cabrera, Michelle T.Corresponding authorDepartment of Ophthalmology, University of Washington, Seattle, WA, USA.

Abstract

Purpose: To determine whether neonatal optic disc morphology measured with handheld spectral-domain OCT (SD-OCT) predicts long-term visual acuity (VA) and refractive outcomes in premature infants. Design: Secondary retrospective analysis of an observational study. Subjects: Premature infants undergoing routine retinopathy of prematurity screening at a tertiary neonatal intensive care unit. Methods: Handheld SD-OCT was performed at approximately 36 weeks’ postmenstrual age (PMA). A semiautomated algorithm quantified optic disc diameter, cup depth, and cup-to-disc ratio (CDR). Visual acuity and cycloplegic refraction were assessed at 9 months, 2 years, and 5 years. Main Outcome Measures: Visual acuity and spherical equivalent (SE) at 9 months, 2 years, and 5 years. Results: The study included 132 eyes from 66 premature infants. The mean disc diameter at 36 weeks’ PMA was 1829 ± 270 μm, cup depth 517 ± 382 μm, and CDR 0.50 ± 0.24. The mean logarithm of the minimum angle of resolution VA was 0.69 ± 0.18 at 9 months, 0.65 ± 0.17 at 2 years, and 0.10 ± 0.15 at 5 years. The mean SE was 1.68 ± 1.54 diopters (D), 0.82 ± 1.87 D, and 0.58 ± 1.30 D, respectively. Optic disc metrics were not associated with VA or SEs at 9 months (n = 52 eyes) or 2 years (n = 39; P > 0.18). They did not predict VA at 5 years (n = 23; P > 0.37). At 5 years, however, greater neonatal cup depth and higher CDR were significantly associated with increased hyperopia (n = 27; P = 0.006 and P = 0.02, respectively), while disc diameter was not. Neonatal sepsis and intraventricular hemorrhage independently predicted poorer VA at 5 years (P = 0.04 and P = 0.001, respectively). Conclusions: Acknowledging a high lost to follow-up rate, neonatal optic disc morphology was not predictive of VA outcomes but was associated with refractive development, with deeper cups and larger CDRs linked to greater hyperopia at 5 years. These findings suggest novel biomarkers for refractive development in the preterm population that deserve further exploration. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Keywords

Cup-to-disc ratioPremature infantsRefractive errorSpectral-domain OCTVisual acuity

Identifiers

Scopus EID
2-s2.0-105041548076