Skip to content

Effects of the induced magnetic field on the defect signals in RFECT system for pipeline inspection

Document Type
Publications · Conference Paper
Registered DB
Scopus
Citation
Scopus 0

Authors

  1. Kim, Hui MinFirst authorPusan National University, School of Electrical and Computer Engineering, Busan, South Korea
  2. Lee, Yu KiDefense Agency for Technology and Quality, Changwon, South Korea
  3. Ryu, Jae HoPusan National University, School of Electrical and Computer Engineering, Busan, South Korea
  4. Park, Gwan SooCorresponding authorPusan National University, School of Electrical and Computer Engineering, Busan, South Korea

Abstract

The RFECT(Remote Field Eddy Current Testing) is based on a phenomenon that occurs around a solenoidal exciter coil and receiving sensor coils in conductive pipe. There is remote field zone in which the eddy current distributions are concentrated on the outer pipe wall. So, it is possible to detect a defect which occurs on the outer surface of pipe wall even if receiving coils are located in the interior of the pipe. The magnitude of induced magnetic field at sensor coils are very important for detecting defect size. This paper deals with effects of the induced magnetic field on the sensing signals in RFECT system with respect to the size variation of defects. The magnitude and the distribution pattern of defect signals are computed by finite element method considering lock-in amplifier circuit. Simulated results in this paper agreed well with measuring ones.

Keywords

Eddy current analysisFinite element methodPipelineRemote field eddy testing

Identifiers

Scopus EID
2-s2.0-85011958786