Skip to content

Separation analysis of metabolites in body fluids using a disposable electrodynamic microfluidic nonenzymatic channel sensor based on time-resolved square-wave voltammetry

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Citation
Web of Science 4Scopus 4
FWCI (Scopus)
0.81
JCR IF
JCR 2024 7.7
ISSN
0925-4005

Authors

  1. Karim, Md MobarokFirst authorPusan Natl Univ, Dept Chem Mat, Busan 46241, South Korea
  2. Sahin, Md Ali ZaberPusan Natl Univ, Chem Inst Funct Mat, Busan 46241, South Korea
  3. Seo, KyeongDeokPusan Natl Univ, Chem Inst Funct Mat, Busan 46241, South Korea
  4. Park, Deog-SuPusan Natl Univ, Chem Inst Funct Mat, Busan 46241, South Korea
  5. Kim, Kwang BokCorresponding authorKorea Inst Ind Technol, Digital Hlth Care R&D Dept, Cheonan 31056, South Korea
  6. Shim, YoonboCorresponding authorPusan Natl Univ, Chem Inst Funct Mat, Busan 46241, South Korea

Abstract

A new separation analysis method was developed for the determination of metabolites in body fluids using a disposable electrodynamic capillary microfluidic channel (ECMC) sensor based on time-resolved square wave voltammetry (trSWV). To detect each target separated in the microfluidic channel using voltammetry, the SWVs were iteratively recorded over the redox potential ranges for all targets until complete separation, then the time-dependent response currents of multiple analytes were converted to an elution curve. For the non-enzymatic detection of metabolites including lactate, glucose, uric acid, and urea, several nanostructured Au alloys anchored on functionalized conductive polyterthiophene benzoate (pTBA) were examined for their catalytic activities. Among them, the AuCuCo alloy revealed the best catalytic performance for the oxidation of metabolites, so it was intensively characterized using surface analysis and electrochemical methods. After that, the separation and detection variables, including AC frequency, AC amplitude, pH, temperature, and metal alloy deposition conditions, were optimized for the ECMC and sensor. The trSWV-based ECMC system precisely separated and detected urea (52.5 ± 3.2 s), lactate (91.0 ± 2.4 s), uric acid (115.5 ± 1.9 s), and glucose (133.0 ± 2.8 s) according to molecular weight. In this system, dynamic ranges were obtained from 0.5 to 40.0 mM and 0.05–5.0 mM, with the detection limits (LODs) of 170.0 ± 4.8 µM, 37.0 ± 1.9 µM for lactate and glucose. Otherwise, urea and uric acid revealed the dynamic ranges of 1.0–50.0 mM, and 10.0–250.0 µM with LODs of 0.31 ± 0.07 mM and 0.27 ± 0.1 µM. Finally, the reliability of the proposed method was evaluated with sweat and saliva samples, demonstrating consistency with the results from high-performance liquid chromatography at 95 % confidence level.

Keywords

Capillary forceElectrodynamic microfluidic sensorLactate and glucoseNon-enzymatic sensorTime-resolved square wave voltammetry (trSWV)Urea and uric acidGLUCOSELACTATEALLOY

Identifiers

Scopus EID
2-s2.0-105012904972
WoS UID
001548955100001