Skip to content

Enhancing the thermodynamic efficiency of hydrogen liquefaction via modifying precooling cycle configuration

Document Type
Publications · Journal Article
Registered DB
SCIEScopus
Journal Ranking
JCR Q1Scopus Q1
Journal
APPLIED THERMAL ENGINEERING277 · 2025
Citation
Web of Science 9Scopus 10
FWCI (Scopus)
1.73
JCR IF
JCR 2024 6.9
ISSN
1359-4311

Authors

  1. Sihwan, ParkFirst authorPusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon Gil, Busan 46241, South Korea
  2. Jeongheon, KimPusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon Gil, Busan 46241, South Korea
  3. Jeong, MinseoGS Engn & Construct Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  4. Kim, HaksungGS Engn & Construct Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  5. Choi, MoonsukGS Engn & Construct Corp, Decarbonizat Solut Team, 2477 Nambusunhwan Ro, Seoul 06725, South Korea
  6. Lee, InkyuCorresponding authorPusan Natl Univ, Sch Chem Engn, 2 Busandaehak Ro,63beon Gil, Busan 46241, South Korea

Abstract

Hydrogen liquefaction is a cornerstone technology that enables large-scale hydrogen transportation and storage; however, its substantial energy demand remains a significant obstacle to widespread industrial deployment. In mixed refrigerant-based liquefaction processes, the refrigerant composition is perceived as a critical parameter influencing energy efficiency. Especially, increasing the proportion of high-boiling-point components in the refrigerant has been shown to effectively reduce the energy required for compression. Nevertheless, this approach poses challenges related to liquid formation during the compression process, which necessitates effective management solutions. This study investigated two design approaches for addressing liquid-phase management following first flashing for application in a flashing mixed refrigerant cycle: Proposed design 1 employs additional pumping, while Proposed design 2 utilizes direct expansion. Each design was optimized, achieving specific energy consumptions of 8.835 and 8.937 kWh/kg, respectively, corresponding to reductions of 4.47 % and 3.37 % compared to the base case design. Under these conditions, the exergy efficiencies of proposed designs achieved 35.57 % and 35.12 %, respectively. These results demonstrate how the shifting of compression load reduces the precooling energy consumption. As one possible option for improving efficiency, this study contributes to advancing the development of efficient and scalable hydrogen liquefaction technologies.

Keywords

Flashing mixed refrigerantHydrogen liquefaction processPrecooling cycleProcess optimizationThermodynamic analysisREFRIGERANTCONVERSIONENERGYOPTIMIZATIONLIQUEFIERSTORAGEEXERGYDESIGN

Identifiers

Scopus EID
2-s2.0-105007144065
WoS UID
001506883600007